Fachartikel in der Zeitschrift Membranes, online erschienen am 25.03.2023. Verfasst von Rongfeng Liang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devic…. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Science and Technology Research Project of Guangzhou, Department of Science and Technology of Guangdong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The level of hydrogen ions in sweat is one of the most important physiological indexes for the health state of the human body. As a type of two-dimensional (2D) material, MXene has the advantages of superior electrical conductivity, a large surface area, and rich functional groups on the surface. Herein, we report a type of Ti3C2Tx-based potentiometric pH sensor for wearable sweat pH analysis. The Ti3C2Tx was prepared by two etching methods, including a mild LiF/HCl mixture and HF solution, which was directly used as the pH-sensitive materials. Both etched Ti3C2Tx showed a typical lamellar structure and exhibited enhanced potentiometric pH responses compared with a pristine precursor of Ti3AlC2. The HF-Ti3C2Tx disclosed the sensitivities of −43.51 ± 0.53 mV pH–1 (pH 1–11) and −42.73 ± 0.61 mV pH–1 (pH 11–1). A series of electrochemical tests demonstrated that HF-Ti3C2Tx exhibited better analytical performances, including sensitivity, selectivity, and reversibility, owing to deep etching. The HF-Ti3C2Tx was thus further fabricated as a flexible potentiometric pH sensor by virtue of its 2D characteristic. Upon integrating with a solid-contact Ag/AgCl reference electrode, the flexible sensor realized real-time monitoring of pH level in human sweat. The result disclosed a relatively stable pH value of ~6.5 after perspiration, which was consistent with the ex situ sweat pH test. This work offers a type of MXene-based potentiometric pH sensor for wearable sweat pH monitoring.

Schlagwörter

Stichwörter der Autor:innen

MXeneion-selective electrodespotentiometric sensorwearable sensors

Autor:innen und Institutionen

  • Guangdong Engineering Technology Research Center for Photoelectric Sensing Materials & Devices, Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Ch…

ORCID-Profile: Shiyu Gan, Li Niu

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Research Project of Guangzhou
  • Department of Science and Technology of Guangdong Province
  • Key Discipline of Materials Science and Engineering, Bureau of Education of Guangzhou

Zitieren

APA

Liang, R., Zhong, L., Zhang, Y., Tang, Y., Lai, M., Han, T., Wang, W., Bao, Y., Ma, Y., Gan, S., & Niu, L. (2023). Directly Using Ti3C2Tx MXene for a Solid-Contact Potentiometric pH Sensor toward Wearable Sweat pH Monitoring. Membranes, 13(4), 376. https://doi.org/10.3390/membranes13040376

Vancouver

Liang R, Zhong L, Zhang Y, Tang Y, Lai M, Han T, et al. Directly Using Ti3C2Tx MXene for a Solid-Contact Potentiometric pH Sensor toward Wearable Sweat pH Monitoring. Membranes. 2023;13(4):376. doi:10.3390/membranes13040376

BibTeX
@article{Liang2023,
  author = {Liang, Rongfeng and Zhong, Lijie and Zhang, Yirong and Tang, Yitian and Lai, Meixue and Han, Tingting and Wang, Wei and Bao, Yu and Ma, Yingming and Gan, Shiyu and Niu, Li},
  title = {Directly Using Ti3C2Tx MXene for a Solid-Contact Potentiometric pH Sensor toward Wearable Sweat pH Monitoring},
  journal = {Membranes},
  year = {2023},
  volume = {13},
  number = {4},
  pages = {376},
  doi = {10.3390/membranes13040376}
}