Agreement of Electrolyte Measurements Between Arterial Blood Gas Analyzers and Central Laboratories in Critically Ill Patients with Acute Kidney Injury
Medical Sciences · 2026
DOI: 10.3390/medsci14030383 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Medical Sciences, 2026. Verfasst von Atthaphong Phongphithakchai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Nephrology Unit, Division of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand. Hauptthemen laut MEDLINE: Acute Kidney Injury, Electrolytes, Blood Gas Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Electrolyte disturbances are common in critically ill patients with acute kidney injury (AKI) and often require urgent intervention. Arterial blood gas (ABG) analyzers provide rapid point-of-care electrolyte measurements, but their agreement with central laboratory analyzers in critically ill patients with AKI remains uncertain. This study evaluated the agreement between ABG and central laboratory measurements of sodium (Na+), potassium (K+), and chloride (Cl−).
Methods
We conducted a retrospective observational study of adult critically ill patients with AKI admitted to a tertiary university hospital ICU between January 2013 and June 2024. Patients with paired electrolyte measurements obtained from an ABG analyzer (ABL800 Basic, Radiometer) and a central laboratory analyzer (Abbott Alinity) within 10 min were included. Agreement was assessed using Bland–Altman analysis and Passing–Bablok regression.
Results
A total of 1870 critically ill patients with AKI were included. The mean bias (95% limits of agreement [LOA]) between ABG and central laboratory measurements was −0.68 mmol/L (−11.41 to 10.06) for sodium, −0.17 mmol/L (−1.46 to 1.12) for potassium, and 7.18 mmol/L (−4.15 to 18.51) for chloride. Potassium showed the narrowest LOA. Pearson correlation coefficients were 0.736, 0.642, and 0.728 for sodium, potassium, and chloride, respectively. Clinically meaningful discrepancies were observed in 7.0% of sodium, 14.1% of potassium, and 31.4% of chloride measurements.
Conclusions
ABG-derived sodium and potassium measurements showed relatively good agreement with central laboratory measurements, particularly for potassium. However, clinically meaningful discrepancies occurred in a subset of measurements, suggesting that preanalytical factors and specimen quality may influence measurement reliability. ABG-derived electrolyte measurements may support rapid bedside assessment, whereas central laboratory measurements remain the reference standard.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nephrology Unit, Division of Internal Medicine, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand.
- School of Allied Health Sciences, Walailak University, Nakhon Si Thammarat 80161, Thailand.
- Research Excellence Center for Innovation and Health Products, Walailak University, Nakhon Si Thammarat 80161, Thailand.
- Medical Technology Program, Faculty of Science, Nakhon Phanom University, Nakhon Phanom 48000, Thailand.
- Faculty of Medicine, Mahasarakham University, Mahasarakham 44000, Thailand.
- Department of Regulatory Biochemistry, Kitasato University Graduate School of Medical Sciences, Sagamihara 252-0373, Japan.
ORCID-Profile: Atthaphong Phongphithakchai, Chutima Jansakun, Wiyada Kwanhian Klangbud, Jongkonnee Thanasai, Fumitaka Kawakami, Moragot Chatatikun
Zitieren
APA
Phongphithakchai, A., Thingphom, S., Tedasen, A., Jansakun, C., Klangbud, W. K., Thanasai, J., Kawakami, F., & Chatatikun, M. (2026). Agreement of Electrolyte Measurements Between Arterial Blood Gas Analyzers and Central Laboratories in Critically Ill Patients with Acute Kidney Injury. Medical Sciences. https://doi.org/10.3390/medsci14030383
Vancouver
Phongphithakchai A, Thingphom S, Tedasen A, Jansakun C, Klangbud WK, Thanasai J, et al. Agreement of Electrolyte Measurements Between Arterial Blood Gas Analyzers and Central Laboratories in Critically Ill Patients with Acute Kidney Injury. Medical Sciences. 2026. doi:10.3390/medsci14030383
BibTeX
@article{Phongphithakchai2026,
author = {Phongphithakchai, Atthaphong and Thingphom, Sitthikorn and Tedasen, Aman and Jansakun, Chutima and Klangbud, Wiyada Kwanhian and Thanasai, Jongkonnee and Kawakami, Fumitaka and Chatatikun, Moragot},
title = {Agreement of Electrolyte Measurements Between Arterial Blood Gas Analyzers and Central Laboratories in Critically Ill Patients with Acute Kidney Injury},
journal = {Medical Sciences},
year = {2026},
doi = {10.3390/medsci14030383}
}