EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Digital Manufacturing and Periodontal Performance of CAD/CAM-Customized Orthodontic Molar Bands Compared with Standard Stainless-Steel Bands

Sorana Maria Bucur iD, Clara Diana Haddad, Loredana Mițariu, Mihai Mițariu, Mariana Păcurar

Medicina · 15.05.2026 · 62 (5) · 967

DOI: 10.3390/medicina62050967 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Medicina, online erschienen am 15.05.2026. Verfasst von Sorana Maria Bucur und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Faculty of Medicine, "Dimitrie Cantemir" University of Târgu Mureș, 3-5 Bodoni Sandor Str., 540545 Târgu-Mureș, Romania. Hauptthemen laut MEDLINE: Stainless Steel, Computer-Aided Design, Molar, Orthodontic Brackets. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Conventional stainless-steel orthodontic molar bands may exhibit limited anatomical adaptation, favoring plaque retention and periodontal inflammation. This study aimed to compare the periodontal outcomes of standard bands and CAD/CAM-customized molar bands in adolescents. Materials and Methods: A prospective randomized controlled clinical study was conducted in 180 adolescents (mean age: 11.9 years) undergoing fixed orthodontic therapy. Participants were allocated to CAD/CAM-customized bands (n = 90) or standard stainless-steel bands (n = 90). Periodontal parameters—Plaque Control Record (PCR), Bleeding on Probing (BOP), and Periodontal Probing Depth (PPD)—were assessed at baseline, 1, 3, and 6 months. Data were analyzed using the Mann–Whitney U test (p < 0.05).

Results

Baseline values were comparable between groups (p > 0.05). During follow-up, the CAD/CAM group showed significantly lower PCR, BOP, and PPD values. At 6 months, PCR was 21 ± 8% vs. 42 ± 12%, BOP was 17 ± 6% vs. 40 ± 10%, and PPD was 2.5 ± 0.5 mm vs. 3.1 ± 0.6 mm (all p < 0.001).

Conclusions

CAD/CAM-customized molar bands demonstrated superior periodontal performance compared with conventional bands. Improved anatomical adaptation may reduce plaque accumulation and gingival inflammation during orthodontic treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stainless SteelComputer-Aided DesignMolarOrthodontic BracketsOrthodontic Appliance DesignHumansProspective StudiesFemaleAdolescentChildMalePeriodontal IndexDental Plaque

Stichwörter der Autor:innen

CAD/CAM manufacturingdigital dentistryorthodontic appliancesorthodontic bandsperiodontal healthstainless-steel biomaterials

Substanzen

Stainless Steel

Autor:innen und Institutionen

  • Department of Dentistry, Faculty of Medicine, "Dimitrie Cantemir" University of Târgu Mureș, 3-5 Bodoni Sandor Str., 540545 Târgu-Mureș, Romania.
  • Department of Orthodontics, Faculty of Dentistry, "Grigore T. Popa" University of Medicine and Pharmacy Iași, 700115 Iași, Romania.
  • Department IV of Dental Medicine and Nursing, Faculty of Dentistry, University of Sibiu "Lucian Blaga" (ULBS), Lucian Blaga 2A, 550169 Sibiu, Romania.
  • Department of Orthodontics, Faculty of Dental Medicine, "George Emil Palade" University of Medicine and Pharmacy, Sciences and Technology, 540139 Târgu-Mureș, Romania.

ORCID-Profile: Sorana Maria Bucur

Zitieren

APA

Bucur, S. M., Haddad, C. D., Mițariu, L., Mițariu, M., & Păcurar, M. (2026). Digital Manufacturing and Periodontal Performance of CAD/CAM-Customized Orthodontic Molar Bands Compared with Standard Stainless-Steel Bands. Medicina, 62(5), 967. https://doi.org/10.3390/medicina62050967

Vancouver

Bucur SM, Haddad CD, Mițariu L, Mițariu M, Păcurar M. Digital Manufacturing and Periodontal Performance of CAD/CAM-Customized Orthodontic Molar Bands Compared with Standard Stainless-Steel Bands. Medicina. 2026;62(5):967. doi:10.3390/medicina62050967

BibTeX
@article{Bucur2026,
  author = {Bucur, Sorana Maria and Haddad, Clara Diana and Mițariu, Loredana and Mițariu, Mihai and Păcurar, Mariana},
  title = {Digital Manufacturing and Periodontal Performance of CAD/CAM-Customized Orthodontic Molar Bands Compared with Standard Stainless-Steel Bands},
  journal = {Medicina},
  year = {2026},
  volume = {62},
  number = {5},
  pages = {967},
  doi = {10.3390/medicina62050967}
}
Kostenlos starten →