Combined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation
Medicina · 2026
DOI: 10.3390/medicina62010212 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medicina, 2026. Verfasst von Bong Gun Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hanyang University College of Medicine, 222 Wangsimni-ro, Seoul 04763, Republic of Korea. Hauptthemen laut MEDLINE: Acromioclavicular Joint, Bone Plates, Coracoid Process, Bone Screws. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research fund of Hanyang University.
Abstract (Originalsprache)
Background and Objectives: Coracoid process (CP) fractures combined with acromioclavicular (AC) joint dislocation are extremely rare, and evidence guiding optimal surgical management remains limited. This retrospective, single-center case series study evaluated clinical and radiologic outcomes after simultaneous fixation of both lesions using a clavicular hook plate and a coracoid screw. Materials and Methods: We retrospectively reviewed 15 consecutive patients with Ogawa type I CP fractures combined with AC joint dislocation who underwent clavicular hook plate and coracoid screw fixation between March 2019 and May 2024. Clinical outcomes at final follow-up included shoulder range of motion (ROM), visual analog scale (VAS) for pain, and the Constant score. Radiologic outcomes included CP union confirmed by computed tomography (CT) and residual AC joint subluxation.
Results
The cohort comprised 13 men and 2 women with a mean age of 55.2 years, and the mean final follow-up was 40.2 months. At final follow-up, mean ROM was 168° for forward elevation, 161° for abduction, and 69° for external rotation at the side, with internal rotation to L1. The mean VAS score was 0.4 and the mean Constant score was 97. CT-confirmed union of the CP fracture was achieved in all patients, and no residual AC joint subluxation was observed. All patients returned to sports and activities of daily living.
Conclusions
In this series, simultaneous fixation using a clavicular hook plate and a coracoid screw provided reliable stabilization for CP fractures with AC joint dislocation, achieving consistent CP union, restoration of AC joint alignment, and favorable clinical outcomes. However, given the retrospective, non-comparative study design, these findings should be interpreted with caution, and further comparative studies are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Hanyang University College of Medicine, 222 Wangsimni-ro, Seoul 04763, Republic of Korea.
- Department of Orthopaedic Surgery, Hanyang University Guri Hospital, 153 Gyeongchun-ro, Guri-si 11923, Republic of Korea.
- Department of Orthopaedic Surgery, Ajou University School of Medicine, 164 World Cup-ro, Suwon 16499, Republic of Korea.
ORCID-Profile: Young Seok Lee, Wan-Sun Choi, Young-Hoon Jo
Förderung
- Research fund of Hanyang University
Zitieren
APA
Lee, B. G., Lee, Y. S., Lee, C. H., Choi, W. S., Woo, C. W., & Jo, Y. H. (2026). Combined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation. Medicina. https://doi.org/10.3390/medicina62010212
Vancouver
Lee BG, Lee YS, Lee CH, Choi WS, Woo CW, Jo YH. Combined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation. Medicina. 2026. doi:10.3390/medicina62010212
BibTeX
@article{Lee2026,
author = {Lee, Bong Gun and Lee, Young Seok and Lee, Chang-Hun and Choi, Wan-Sun and Woo, Chang-Woo and Jo, Young-Hoon},
title = {Combined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation},
journal = {Medicina},
year = {2026},
doi = {10.3390/medicina62010212}
}
EUVIMED