Das Review zeigt: KI-Modelle auf Sinusrhythmus-EKGs erkennen okkultes Vorhofflimmern und sagen neues Vorhofflimmern mit moderater bis hoher Genauigkeit voraus. Die meisten Studien waren retrospektiv.

Fragestellung

Wie gut erkennen und prognostizieren KI-Modelle auf Sinusrhythmus-EKGs paroxysmales bzw. neu auftretendes Vorhofflimmern?

Methode

Scoping Review mit Suche in MEDLINE, Embase, Web of Science, Scopus und IEEE Xplore bis November 2025; eingeschlossen waren Originalstudien zu Sinusrhythmus-EKGs und AF.

Ergebnisse

19 Studien. Für subklinisches AF lag die AUROC bei 0,75–0,90 (10 Studien); für neues AF bei 0,69–0,85 (6 Studien). Externe Validierung wurde in 11 Studien berichtet.

Einschränkungen

Retrospektives Design, Patientenselektion, begrenzte Angaben zur Kalibrierung und wenige prospektive Daten zum klinischen Nutzen.

Schlussfolgerung der Autor:innen

KI-basierte Analysen von Sinusrhythmus-EKGs können okkultes AF erkennen und das zukünftige AF-Risiko mit moderater bis hoher Genauigkeit stratifizieren; prospektive Studien sind vor breiter Anwendung erforderlich.

Kernaussagen

  • Subklinisches AF: AUROC 0,75–0,90 in 10 Studien
  • Neues AF: AUROC 0,69–0,85 in 6 Studien
  • Externe Validierung in 11 Studien berichtet

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Scoping Review in der Zeitschrift Medicina, online erschienen am 17.01.2026. Verfasst von Ziga Mrak und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Clinical Centre Maribor, Ljubljanska Ulica 5, 2000 Maribor, Slovenia. Hauptthemen laut MEDLINE: Atrial Fibrillation, Electrocardiography, Artificial Intelligence. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Slovenian Research and Innovation Agency.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Subclinical paroxysmal atrial fibrillation (AF) is often undetected by conventional screening strategies, until complications emerge. Artificial intelligence (AI) applied to sinus rhythm electrocardiograms has emerged as a promising tool to identify individuals with occult AF and to predict the risk of future incident AF. This scoping review synthesizes evidence from original studies evaluating AI models trained on sinus rhythm ECGs for AF detection or AF prediction. Materials and Methods: A comprehensive search of MEDLINE, Embase, Web of Science, Scopus, and IEEE Xplore was conducted to identify peer-reviewed studies from inception to November 2025. Eligible studies included original investigations in which the model input was a sinus rhythm ECG and the outcome was either paroxysmal AF or new-onset AF. Extracted variables included cohort characteristics, ECG acquisition parameters, AI architecture, model predictive performance, AF prediction horizon, clinical outcomes, and validation strategy. Risk of bias was assessed using PROBAST.

Results

Nineteen studies met the inclusion criteria. Retrospective datasets ranging from several thousand to over one million ECGs and convolutional or deep neural network AI architectures were used in most studies. AI-ECG models demonstrated high diagnostic accuracy for detecting subclinical AF (ten studies; AUROC 0.75–0.90) and for predicting long-term new-onset AF (six studies; AUROC 0.69–0.85) from a single sinus rhythm ECG. Robust external validation was reported in eleven studies. Combining AI-ECG models with clinical risk factors improved AF predictive performance in several reports. Key limitations across studies included retrospective design, patient selection, limited calibration reporting, and sparse prospective impact data.

Conclusions

AI-based analysis of sinus rhythm ECGs can detect occult AF and stratify future AF risk with moderate-to-high accuracy across multiple populations and healthcare systems. However, rigorous prospective trials, evaluating clinical benefit, cost-effectiveness, calibration across demographic groups, and real-world implementation, are required before broad adoption in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationElectrocardiographyArtificial IntelligenceHumans

Stichwörter der Autor:innen

ECGartificial intelligenceatrial fibrillationdeep learningscoping review

Autor:innen und Institutionen

  • Department of Cardiology, University Clinical Centre Maribor, Ljubljanska Ulica 5, 2000 Maribor, Slovenia.
  • Faculty of Medicine, University of Maribor, Taborska Ulica 8, 2000 Maribor, Slovenia.

ORCID-Profile: Dejan Dinevski

Förderung

  • Slovenian Research and Innovation Agency

Zitieren

APA

Mrak, Z., Naji, F. H., & Dinevski, D. (2026). Artificial Intelligence Applied to Electrocardiograms Recorded in Sinus Rhythm for Detection and Prediction of Atrial Fibrillation: A Scoping Review. Medicina, 62(1), 199. https://doi.org/10.3390/medicina62010199

Vancouver

Mrak Z, Naji FH, Dinevski D. Artificial Intelligence Applied to Electrocardiograms Recorded in Sinus Rhythm for Detection and Prediction of Atrial Fibrillation: A Scoping Review. Medicina. 2026;62(1):199. doi:10.3390/medicina62010199

BibTeX
@article{Mrak2026,
  author = {Mrak, Ziga and Naji, Franjo Husam and Dinevski, Dejan},
  title = {Artificial Intelligence Applied to Electrocardiograms Recorded in Sinus Rhythm for Detection and Prediction of Atrial Fibrillation: A Scoping Review},
  journal = {Medicina},
  year = {2026},
  volume = {62},
  number = {1},
  pages = {199},
  doi = {10.3390/medicina62010199}
}
Kostenlos starten →