Real-World Clinical Utility of a Methylated DNA Biomarker Assay on Samples Collected with a Swallowable Capsule-Balloon for Detection of Barrett’s Esophagus (BE)
Medicina · 13.12.2024 · 60 (12) · 2052
DOI: 10.3390/medicina60122052 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Medicina, online erschienen am 13.12.2024. Verfasst von Dan Lister und 8 weiteren Autor:innen. Beteiligte Einrichtung: Arkansas Heartburn Treatment Center, Heber Springs, AR 72543, USA. Hauptthemen laut MEDLINE: Barrett Esophagus. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Barrett’s Esophagus (BE) is the only known precursor for esophageal adenocarcinoma (EAC). Patients with multiple risk factors for BE/EAC are recommended for screening; however, few eligible patients undergo evaluation by endoscopy. EsoGuard® (EG) is a commercially available biomarker assay used to analyze esophageal cells collected non-endoscopically with EsoCheck® (EC) for the qualitative detection of BE/EAC. This study evaluates the real-world clinical utility of EG on cells collected with EC in patients defined by U.S. gastroenterology societies to be at-risk for BE and EAC.
Methods
This multi-center, observational CLinical Utility of EsoGuard (CLUE) study enrolled screening-eligible patients as defined by the American College of Gastroenterology (ACG) and the American Gastroenterological Association (AGA). Clinical utility was evaluated by the provider decision impact of EG and additionally by assessing patient compliance outcomes with recommended follow-up testing.
Results
There were 551 patients enrolled, with a mean age of 62.0 ± 12.4 years and 56.1% (309/551) meeting ACG guideline criteria for BE screening. EC cell collection was successful in 97.1% (535/551), among which the EG positivity rate was 27.3% (n = 146). The provider decision impact was high, with 100% of EG-positive patients being referred for esophagogastroduodenoscopy (EGD), while 98% of EG negative patients were not referred. Among the EG-positive patients, the overall compliance with follow-up EGD was 85.4%.
Conclusions
Combining EC non-endoscopic esophageal cell collection with the EG biomarker assay is effective in guiding provider decision-making for the detection of BE and EAC. Patients with positive EG results demonstrate high compliance with recommended follow-up EGD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Arkansas Heartburn Treatment Center, Heber Springs, AR 72543, USA.
- Colorado Primary Health Care, Littleton, CO 80120, USA.
- Center for Digestive Disease, Shenandoah, TX 77384, USA.
- Savii Health, Savannah, GA 31406, USA.
- Lucid Diagnostics Inc., New York, NY 10017, USA.
ORCID-Profile: Dan Lister, Victoria T Lee, Suman Verma
Zitieren
APA
Lister, D., Fine, A., Maheshwari, S., Bradley, P. S., Lister, K., Lee, V. T., deGuzman, B. J., Verma, S., & Aklog, L. (2024). Real-World Clinical Utility of a Methylated DNA Biomarker Assay on Samples Collected with a Swallowable Capsule-Balloon for Detection of Barrett’s Esophagus (BE). Medicina, 60(12), 2052. https://doi.org/10.3390/medicina60122052
Vancouver
Lister D, Fine A, Maheshwari S, Bradley PS, Lister K, Lee VT, et al. Real-World Clinical Utility of a Methylated DNA Biomarker Assay on Samples Collected with a Swallowable Capsule-Balloon for Detection of Barrett’s Esophagus (BE). Medicina. 2024;60(12):2052. doi:10.3390/medicina60122052
BibTeX
@article{Lister2024,
author = {Lister, Dan and Fine, Andy and Maheshwari, Shail and Bradley, Paul S and Lister, Kimberly and Lee, Victoria T and deGuzman, Brian J and Verma, Suman and Aklog, Lishan},
title = {Real-World Clinical Utility of a Methylated DNA Biomarker Assay on Samples Collected with a Swallowable Capsule-Balloon for Detection of Barrett’s Esophagus (BE)},
journal = {Medicina},
year = {2024},
volume = {60},
number = {12},
pages = {2052},
doi = {10.3390/medicina60122052}
}
EUVIMED