DOI: 10.3390/medicina60060969 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Medicina, 2024. Verfasst von Changsik Shin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu 11759, Republic of Korea. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Cannula, Hemorrhage, Myotonic Dystrophy. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objective: Although extracorporeal membrane oxygenation (ECMO) is an essential life-saving technique for patients with refractory cardiopulmonary shock, it can be fatal in certain cases. Case Presentation: A 19-year-old girl treated with ECMO presented with acute limb ischemia 2 days after cannula removal. The decannulation was performed percutaneously by an interventional cardiologist, and the vascular surgery department was consulted after the patient developed symptoms. The first suspected diagnosis was thrombosis due to incorrect use of the closure device. However, the artery had ruptured due to the insertion of a catheter with a cannula that was larger than the patient’s artery. Management and Outcome: Fortunately, excessive bleeding due to the size-mismatched cannula was prevented by an unintentional complication of the closing device, which saved the patient’s life. She underwent a right common femoral artery thrombectomy and patch angioplasty. Hospital guidelines have changed regarding the surgical removal of ECMO cannulas. Discussion: This report aims to highlight the importance of two aspects that are critical to a successful outcome: individualized cannula selection followed by precise insertion and removal and postoperative evaluation of a patient’s final status.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracorporeal Membrane OxygenationCannulaHemorrhageMyotonic DystrophyHumansFemaleYoung AdultFemoral ArteryThrombectomyAdult

Stichwörter der Autor:innen

ECMOcase reportmyotonic dystrophy type 1size mismatchvascular closure device

Autor:innen und Institutionen

  • Department of Surgery, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu 11759, Republic of Korea.
  • Department of Surgery, College of Medicine, Chungbuk National University, Cheongju 28644, Republic of Korea.
  • Department of Surgery, Chungbuk National University Hospital, Cheongju 28644, Republic of Korea.

ORCID-Profile: Kwon Cheol Yoo, Dae Hoon Kim

Zitieren

APA

Shin, C., Yoo, K. C., & Kim, D. H. (2024). Critical Hemorrhage Caused by a Size-Mismatched Extracorporeal Membrane Oxygenation Cannula in a Patient with Myotonic Dystrophy Type 1: A Case Report and Literature Review. Medicina. https://doi.org/10.3390/medicina60060969

Vancouver

Shin C, Yoo KC, Kim DH. Critical Hemorrhage Caused by a Size-Mismatched Extracorporeal Membrane Oxygenation Cannula in a Patient with Myotonic Dystrophy Type 1: A Case Report and Literature Review. Medicina. 2024. doi:10.3390/medicina60060969

BibTeX
@article{Shin2024,
  author = {Shin, Changsik and Yoo, Kwon Cheol and Kim, Dae Hoon},
  title = {Critical Hemorrhage Caused by a Size-Mismatched Extracorporeal Membrane Oxygenation Cannula in a Patient with Myotonic Dystrophy Type 1: A Case Report and Literature Review},
  journal = {Medicina},
  year = {2024},
  doi = {10.3390/medicina60060969}
}
Kostenlos starten →