EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimising Percutaneous Coronary Interventions: The Impact of Stent Type and Diameter on Long-Term Clinical Outcomes in Large Coronary Arteries

Gökhan Gök iD, Murat Akçay iD, Ufuk Yıldırım, Metin Çoksevim iD, Korhan Soylu, Mahmut Şahin iD

Medicina · 2024

DOI: 10.3390/medicina60040600 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medicina, 2024. Verfasst von Gökhan Gök und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinic of Cardiology, Terme State Hospital, 55139 Samsun, Turkey. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention, Drug-Eluting Stents, Stents, Coronary Vessels. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Our study aimed to reveal the effect of using 4 mm bare-metal stents (BMS), 4 mm drug-eluting stents (DES), or 3 mm DES with 4 mm diameter balloon post-dilation strategies on long-term clinical outcomes and endpoints for large-diameter coronary artery percutaneous coronary intervention (PCI). Materials and Methods: In our study, patients who had undergone PCI were retrospectively screened between January 2014 and July 2020. The study included 350 patients and was divided into three groups; Group I (n = 134) included patients with direct 4.0 mm BMS implantation, Group II (n = 109) included patients with direct 4.0 DES implantation, and Group III (n = 107) included patients with 4mm NC post-dilatation after 3 mm DES implantation. Primary endpoints were determined as target lesion revascularisation, cardiac mortality, and myocardial infarction associated with the target vessel. Our secondary endpoint was all-cause mortality.

Results

No differences were observed between the groups in terms of the baseline variables. Stent length was the highest in Group II and the shortest in Group III. There were no significant differences between the groups regarding major adverse cardiovascular events (MACE).

Conclusions

Our study suggests that in percutaneous coronary interventions for non-complex lesions, there is no significant difference in MACE outcomes when directly implanting a 4 mm diameter DES, a 4 mm diameter BMS, or a 3 mm diameter DES, followed by post-dilation with an appropriately sized NC balloon when the target vessel diameter is in the range of 4 to 4.4 mm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Percutaneous Coronary InterventionDrug-Eluting StentsStentsCoronary VesselsHumansMaleFemaleRetrospective StudiesAgedMiddle AgedTreatment OutcomeCoronary Artery Disease

Stichwörter der Autor:innen

coronary artery diseaselong-term outcomespercutaneous coronary intervention

Autor:innen und Institutionen

  • Clinic of Cardiology, Terme State Hospital, 55139 Samsun, Turkey.
  • Department of Cardiology, Ondokuz Mayıs University Faculty of Medicine, 55200 Samsun, Turkey.

ORCID-Profile: Gökhan Gök, Murat Akçay, Metin Çoksevim, Mahmut Şahin

Zitieren

APA

Gök, G., Akçay, M., Yıldırım, U., Çoksevim, M., Soylu, K., & Şahin, M. (2024). Optimising Percutaneous Coronary Interventions: The Impact of Stent Type and Diameter on Long-Term Clinical Outcomes in Large Coronary Arteries. Medicina. https://doi.org/10.3390/medicina60040600

Vancouver

Gök G, Akçay M, Yıldırım U, Çoksevim M, Soylu K, Şahin M. Optimising Percutaneous Coronary Interventions: The Impact of Stent Type and Diameter on Long-Term Clinical Outcomes in Large Coronary Arteries. Medicina. 2024. doi:10.3390/medicina60040600

BibTeX
@article{Gk2024,
  author = {Gök, Gökhan and Akçay, Murat and Yıldırım, Ufuk and Çoksevim, Metin and Soylu, Korhan and Şahin, Mahmut},
  title = {Optimising Percutaneous Coronary Interventions: The Impact of Stent Type and Diameter on Long-Term Clinical Outcomes in Large Coronary Arteries},
  journal = {Medicina},
  year = {2024},
  doi = {10.3390/medicina60040600}
}
Kostenlos starten →