EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Remimazolam-Based Anesthesia in Patients with Heart Failure Due to Mitral Regurgitation and Low Left Ventricular Function: A Case Series

Atsuhiro Kitaura iD, Hiroatsu Sakamoto, Shinichi Hamasaki, Shota Tsukimoto iD, Yasufumi Nakajima

Medicina · 2023

DOI: 10.3390/medicina59122136 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Medicina, 2023. Verfasst von Atsuhiro Kitaura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Kindai University Faculty of Medicine, Osaka 586-0001, Japan. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Heart Failure, Anesthetics. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Remimazolam is a new ultrashort-acting benzodiazepine anesthetic. Remimazolam appears to be useful in patients with severe valvular disease because of its minimal cardiovascular impact. In this retrospective case series study, we assessed the efficacy and safety of remimazolam for maintaining hemodynamic stability during anesthetic induction and maintenance. Cases: MitraClip was performed on 18 cases with severe mitral regurgitation with low left ventricular function who presented with heart failure, and remimazolam was administered for general anesthesia with induction (12 mg/kg/h) and maintenance (1 mg/kg/h). The impact of remimazolam on the hemodynamics at anesthetic induction and during anesthetic maintenance was investigated retrospectively using electronic medical records. Blood pressure decreased significantly during anesthetic induction with remimazolam (78.5 [72, 81.25] and 66.1 [62.2, 74.2], median [IQR], p = 0.0001), but only mildly, by about 10 mmHg. There was no significant change in the cardiac index (2.0 [1.8, 2.4] vs. 1.9 [1.8, 2.3], p = 0.57642) or pulse rate (73.5 ± 8.85 vs. 74.7 ± 11.7, mean ± SD, p = 0.0876) during anesthetic induction with remimazolam. All patients underwent MitraClip without major hemodynamic concerns, with no or small increases in inotropes. Conclusions: Remimazolam may be used safely in patients with severe mitral regurgitation and low left ventricular function presenting with heart failure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyHeart FailureAnestheticsHumansVentricular Function, LeftRetrospective StudiesTreatment OutcomeBenzodiazepinesAnesthesia, General

Stichwörter der Autor:innen

MitraClipanesthesiaheart failuremitral regurgitationremimazolam

Substanzen

remimazolamBenzodiazepinesAnesthetics

Autor:innen und Institutionen

  • Department of Anesthesiology, Kindai University Faculty of Medicine, Osaka 586-0001, Japan.

ORCID-Profile: Atsuhiro Kitaura, Shota Tsukimoto

Zitieren

APA

Kitaura, A., Sakamoto, H., Hamasaki, S., Tsukimoto, S., & Nakajima, Y. (2023). Remimazolam-Based Anesthesia in Patients with Heart Failure Due to Mitral Regurgitation and Low Left Ventricular Function: A Case Series. Medicina. https://doi.org/10.3390/medicina59122136

Vancouver

Kitaura A, Sakamoto H, Hamasaki S, Tsukimoto S, Nakajima Y. Remimazolam-Based Anesthesia in Patients with Heart Failure Due to Mitral Regurgitation and Low Left Ventricular Function: A Case Series. Medicina. 2023. doi:10.3390/medicina59122136