Fallbericht in der Zeitschrift Medicina, online erschienen am 15.11.2023. Verfasst von Massimo Frosecchi. Beteiligte Einrichtung: Department of Surgical and Diagnostic Sciences (DISC), University of Genoa, 16132 Genoa, Italy. Hauptthemen laut MEDLINE: Magnesium, Titanium. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and objectives: In guided bone regeneration (GBR), large defects comprising both horizontal and vertical components usually require additional mechanical support to stabilize the augmentation and preserve the bone volume. This additional support is usually attained by using non-resorbable materials. A recently developed magnesium membrane presents the possibility of providing mechanical support whilst being completely resorbable. The aim of this case report was to describe the application and outcome of the magnesium membrane in combination with a collagen pericardium membrane for GBR. Materials and methods: A 74 year old, in an otherwise good general health condition, was presented with stage 2 grade A periodontitis and an impacted canine. After extraction of the impacted canine, a defect was created with both vertical and horizontal components. The defect was augmented using the magnesium membrane to create a supportive arch to the underlying bone graft and a collagen pericardium membrane was placed on top to aid with the soft tissue closure.

Results

Upon reentry at 8 months, complete resorption of the magnesium devices was confirmed as there were no visible remnants remaining. A successful augmentation outcome had been achieved as the magnesium membrane in combination with the collagen membrane had maintained the augmented bone well. Two dental implants could be successfully placed in the healed augmentation.

Conclusions

In this case, the magnesium membrane in combination with a collagen pericardium membrane presented a potentially viable alternative treatment to titanium meshes or titanium-reinforced membranes for the augmentation of a defect with both horizontal and vertical components that is completely resorbable. It was demonstrated that it is possible to attain a good quality and quantity of bone using a resorbable system that has been completely resorbed by the time of reentry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnesiumTitaniumHumansAgedBone TransplantationCollagenBone RegenerationMembranes, Artificial

Stichwörter der Autor:innen

bone regenerationmagnesiumperiodontal diseases

Substanzen

MagnesiumTitaniumCollagenMembranes, Artificial

Autor:innen und Institutionen

  • Department of Surgical and Diagnostic Sciences (DISC), University of Genoa, 16132 Genoa, Italy.

Zitieren

APA

Frosecchi, M. (2023). Horizontal and Vertical Defect Management with a Novel Degradable Pure Magnesium Guided Bone Regeneration (GBR) Membrane—A Clinical Case. Medicina, 59(11), 2009. https://doi.org/10.3390/medicina59112009

Vancouver

Frosecchi M. Horizontal and Vertical Defect Management with a Novel Degradable Pure Magnesium Guided Bone Regeneration (GBR) Membrane—A Clinical Case. Medicina. 2023;59(11):2009. doi:10.3390/medicina59112009

BibTeX
@article{Frosecchi2023,
  author = {Frosecchi, Massimo},
  title = {Horizontal and Vertical Defect Management with a Novel Degradable Pure Magnesium Guided Bone Regeneration (GBR) Membrane—A Clinical Case},
  journal = {Medicina},
  year = {2023},
  volume = {59},
  number = {11},
  pages = {2009},
  doi = {10.3390/medicina59112009}
}
Kostenlos starten →