EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Geometry-Dependent Wall Shear Stress in Standardized 50% Coronary Stenoses: Effects of Pressure and Hematocrit in a Parametric CFD Study

Mario Henrique Quim Ferreira, Johannes Gérson Janzen, Valter Aragão do Nascimento

Mathematical and Computational Applications · 07.11.2026 · 31 (6) · 251

DOI: 10.3390/mca31060251 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mathematical and Computational Applications, online erschienen am 07.11.2026. Verfasst von Mario Henrique Quim Ferreira und 2 weiteren Autor:innen. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Angiographically equivalent coronary lesions may not produce equivalent local biomechanical environments. This study tested whether a standardized stenosis generates different wall shear stress (WSS) distributions across geometries under matched pressure conditions. Steady-state computational fluid dynamics simulations used idealized left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA) models derived from human morphometric parameters. Each contained a 50% diameter-reduction stenosis, 18 mm long and 35% eccentric. Diastolic pressures of 70, 90, and 130 mmHg and hematocrit levels of 25%, 45%, and 65% were evaluated using hematocrit-dependent effective Newtonian properties and a distal-to-proximal pressure ratio of 0.86. Blood flow was modeled under steady-state conditions with rigid arterial walls. A patient-derived LAD was included as a secondary analysis. At 130 mmHg and 65% hematocrit, WSS at the corresponding principal stenotic point reached 88.79 Pa in the RCA, 52.21 Pa in the LAD, and 32.18 Pa in the LCX. Changes in the prescribed hematocrit-dependent effective blood properties produced different WSS responses across the geometries. The patient-derived LAD showed comparable relative WSS responses. Thus, in these simulations, equivalent stenosis and pressure ratios did not produce biomechanically equivalent WSS environments. These findings indicate that artery-specific geometry contributes to local wall-shear exposure. Its potential relevance to plaque vulnerability and coronary risk should be assessed in future patient-specific studies incorporating plaque characteristics and clinical outcomes.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil

Zitieren

APA

Ferreira, M. H. Q., Janzen, J. G., & Nascimento, V. A. D. (2026). Geometry-Dependent Wall Shear Stress in Standardized 50% Coronary Stenoses: Effects of Pressure and Hematocrit in a Parametric CFD Study. Mathematical and Computational Applications, 31(6), 251. https://doi.org/10.3390/mca31060251

Vancouver

Ferreira MHQ, Janzen JG, Nascimento VAD. Geometry-Dependent Wall Shear Stress in Standardized 50% Coronary Stenoses: Effects of Pressure and Hematocrit in a Parametric CFD Study. Mathematical and Computational Applications. 2026;31(6):251. doi:10.3390/mca31060251

BibTeX
@article{Ferreira2026,
  author = {Ferreira, Mario Henrique Quim and Janzen, Johannes Gérson and Nascimento, Valter Aragão do},
  title = {Geometry-Dependent Wall Shear Stress in Standardized 50% Coronary Stenoses: Effects of Pressure and Hematocrit in a Parametric CFD Study},
  journal = {Mathematical and Computational Applications},
  year = {2026},
  volume = {31},
  number = {6},
  pages = {251},
  doi = {10.3390/mca31060251}
}
Kostenlos starten →