EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Acoustically Driven Coated Microbubbles in Peristaltic Non-Newtonian Blood Flow: Rupture-Gated Release and Near-Wall Migration

Ahmed K. Abu-Nab, Awatif J. Alqarni, Essam M. Elsaid

Mathematics · 19.11.2026 · 14 (22) · 4263

DOI: 10.3390/math14224263 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mathematics, online erschienen am 19.11.2026. Verfasst von Ahmed K. Abu-Nab und 2 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education of the Russian Federation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasound-driven coated microbubbles are a promising vehicle for targeted drug delivery, yet how peristaltic wall motion, non-Newtonian blood rheology, and shell-resolved bubble dynamics jointly govern delivery remains poorly understood. Resolving this coupling, we identify two operating principles for microbubble-mediated delivery: drug release is gated by shell rupture rather than graded by acoustic amplitude, and near-wall targeting is governed by matching the drive frequency to the shell resonance. At the clinically standard operating point (PA = 120 kPa, f = 2 MHz, mechanical index MI = 0.085) 88% of the payload is released within one acoustic cycle, while the minimum rupture threshold reported here lies below MI = 0.06; for SonoVue-like shells the threshold itself is minimized along the frequency–size locus fopt R0 ≈ 3.9 MHz.μm. We establish these results with a multiscale framework coupling a Carreau–Yasuda peristaltic carrier flow, obtained from a long-wave lubrication reduction, with the Lagrangian dynamics of a coated microbubble governed by the Marmottant–Keller–Miksis equation and a phenomenological rupture-gated release model, integrated with an adaptive stiff solver at acoustic resolution. The rupture threshold, at which the periodic radial orbit first reaches the rupture radius, is mapped in the drive-frequency–pressure plane. Near-wall migration is driven not by the hydrodynamic pressure, which modulates the oscillation by only one part in 105, but by the secondary-Bjerknes attraction: in the continuity-consistent peristaltic carrier field it induces a radial migration of 28% of the vessel radius over three peristaltic periods at the shell resonance of a 1 MHz drive, f shell/f ≈ 1.13, more than an order of magnitude above that of smaller off-resonant bubbles and insensitive to the near-wall regularization. Shear-thinning suppresses the peristaltic pressure variation as S=0.21Cuw−0.48, thirteen-fold at baseline, while reducing the net throughput by only about 10%. These results establish frequency–size matching as the primary lever for rupture-gated release and near-wall migration, with the peristaltic amplitude ratio as a geometric modulator of the wall-directed attraction.

Förderung

  • Ministry of Science and Higher Education of the Russian Federation

Zitieren

APA

Abu-Nab, A. K., Alqarni, A. J., & Elsaid, E. M. (2026). Acoustically Driven Coated Microbubbles in Peristaltic Non-Newtonian Blood Flow: Rupture-Gated Release and Near-Wall Migration. Mathematics, 14(22), 4263. https://doi.org/10.3390/math14224263

Vancouver

Abu-Nab AK, Alqarni AJ, Elsaid EM. Acoustically Driven Coated Microbubbles in Peristaltic Non-Newtonian Blood Flow: Rupture-Gated Release and Near-Wall Migration. Mathematics. 2026;14(22):4263. doi:10.3390/math14224263

BibTeX
@article{AbuNab2026,
  author = {Abu-Nab, Ahmed K. and Alqarni, Awatif J. and Elsaid, Essam M.},
  title = {Acoustically Driven Coated Microbubbles in Peristaltic Non-Newtonian Blood Flow: Rupture-Gated Release and Near-Wall Migration},
  journal = {Mathematics},
  year = {2026},
  volume = {14},
  number = {22},
  pages = {4263},
  doi = {10.3390/math14224263}
}
Kostenlos starten →