EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance Assessment of Current Feedback-Based Active Damping Techniques for Three-Phase Grid-Connected VSCs with LCL Filters

Mustafa Ali, Abdullah Ali Alhussainy, Fahd Hariri, Sultan Alghamdi, Yusuf A. Alturki

Mathematics · 13.08.2025 · 13 (16) · 2592

DOI: 10.3390/math13162592 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mathematics, online erschienen am 13.08.2025. Verfasst von Mustafa Ali und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institutional Fund Projects.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The voltage source converters convert the DC to AC in order to interface distributed generation units with the utility grid, typically using an LCL filter to smooth the modulated wave. However, the LCL filter can introduce resonance, potentially cause instability, and necessitate the use of damping techniques, such as active damping, which utilizes feedback from the current control loop to suppress resonance. This paper presents a comprehensive performance assessment of four current-feedback-based active damping (AD) techniques—converter current feedback (CCF), CCF with capacitor current feedback (CCFAD), grid current feedback (GCF), and GCF with capacitor current feedback (GCFAD)—under a broad range of realistic grid disturbances and low switching frequency conditions. Unlike prior works that often analyze individual feedback strategies in isolation, this study highlights and compares their dynamic behavior, robustness, and total harmonic distortion (THD) in eight operational scenarios. The results reveal the severe instability of GCF in the absence of damping and the superior inherent damping property of CCF while demonstrating the comparable effectiveness of GCFAD. Moreover, a simplified yet robust design methodology for the LCL filter is proposed, enabling the filter to maintain stability and performance even under significant variations in grid impedance. Additionally, a sensitivity analysis of switching frequency variation is included. The findings offer valuable insights into selecting and implementing robust active damping methods for grid-connected converters operating at constrained switching frequencies. The effectiveness of the proposed methods has been validated through both MATLAB/Simulink simulations and hardware-in-the-loop (HIL) testing.

Förderung

  • Institutional Fund Projects

Zitieren

APA

Ali, M., Alhussainy, A. A., Hariri, F., Alghamdi, S., & Alturki, Y. A. (2025). Performance Assessment of Current Feedback-Based Active Damping Techniques for Three-Phase Grid-Connected VSCs with LCL Filters. Mathematics, 13(16), 2592. https://doi.org/10.3390/math13162592

Vancouver

Ali M, Alhussainy AA, Hariri F, Alghamdi S, Alturki YA. Performance Assessment of Current Feedback-Based Active Damping Techniques for Three-Phase Grid-Connected VSCs with LCL Filters. Mathematics. 2025;13(16):2592. doi:10.3390/math13162592

BibTeX
@article{Ali2025,
  author = {Ali, Mustafa and Alhussainy, Abdullah Ali and Hariri, Fahd and Alghamdi, Sultan and Alturki, Yusuf A.},
  title = {Performance Assessment of Current Feedback-Based Active Damping Techniques for Three-Phase Grid-Connected VSCs with LCL Filters},
  journal = {Mathematics},
  year = {2025},
  volume = {13},
  number = {16},
  pages = {2592},
  doi = {10.3390/math13162592}
}
Kostenlos starten →