Abstract (Originalsprache)

In rotary ultrasonic machining, tool clamping and tool geometry affect the resonant frequency and vibration amplitude of ultrasonic tool holders. This study proposes a preliminary analytical design method for an unloaded ultrasonic transducer that approximately incorporates the tapered-bore geometry required to accommodate an ER collet from the ER-series spring-collet system. The influences of tool assembly, tool diameter, and extension length were subsequently examined using finite element modal and harmonic response analyses, together with experimental measurements conducted at 0 rpm without contact between the tool and workpiece during cutting. The simulated resonant frequency of the unloaded transducer was 22,103 Hz, representing a deviation of 0.47% from the design target of 22,000 Hz. Installing a tool with a diameter of 6 mm and an extension length of 30 mm lowered the simulated transducer frequency to 19,665 Hz, representing an 11.03% reduction. Experimentally, tool installation decreased the series resonant frequency of the ultrasonic tool holder from 22,272 to 19,715 Hz, corresponding to a reduction of 2557 Hz (11.48%), which agreed with the downward trend observed in the simulations. Both numerical simulations and experimental results indicated that increasing the tool diameter or extension length lowered the resonant frequency while enhancing the tool-tip vibration amplitude within the investigated range. The measured amplitude also exhibited an approximately linear increase with ultrasonic power under fixed tool conditions. These findings support the application of the analytical model to unloaded-transducer design and provide stationary, unloaded baseline characteristics when selecting tools and determining operating frequencies.

Förderung

  • National Defense Basic Scientific Research Program of China

Zitieren

APA

Wu, S., Wang, A., Liu, Z., Ruan, K., & Shan, Q. (2026). Theoretical Design and Experimental Validation of an Ultrasonic Tool Holder Assembled with a Collet for Rotary Ultrasonic Machining. Machines, 14(12), 1388. https://doi.org/10.3390/machines14121388

Vancouver

Wu S, Wang A, Liu Z, Ruan K, Shan Q. Theoretical Design and Experimental Validation of an Ultrasonic Tool Holder Assembled with a Collet for Rotary Ultrasonic Machining. Machines. 2026;14(12):1388. doi:10.3390/machines14121388

BibTeX
@article{Wu2026,
  author = {Wu, Shihao and Wang, Aimin and Liu, Zepeng and Ruan, Kaiyi and Shan, Qishen},
  title = {Theoretical Design and Experimental Validation of an Ultrasonic Tool Holder Assembled with a Collet for Rotary Ultrasonic Machining},
  journal = {Machines},
  year = {2026},
  volume = {14},
  number = {12},
  pages = {1388},
  doi = {10.3390/machines14121388}
}
Kostenlos starten →