EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic Characteristics and Resonance Risk Assessment of a Large-Scale Vertical Pumping Station Structure

Kexin Kuang, Sen Du, Xuanwen Jia, Bowen Zhang, Longyu Li, Weixuan Jiao

Machines · 29.05.2026 · 14 (6) · 618

DOI: 10.3390/machines14060618 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Machines, online erschienen am 29.05.2026. Verfasst von Kexin Kuang und 5 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Research Fund Program of State Key Laboratory of Water Disaster Prevention, Jiangsu Province Young Scientific and Technological Talent Lifting Project, Yangzhou University Qing Lan Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pumping stations serve as the foundation platform for large-scale vertical fluid machinery, and their structural dynamics directly govern the vibration levels and long-term reliability of the installed pump units. In low-head vertical pumping stations, the interaction among the massive underwater substructure, flexible above-ground powerhouse, and surrounding backfill soil creates a complex dynamic system whose behavior remains insufficiently characterized. This study presents a comprehensive dynamic analysis of a large-scale vertical pumping station using a high-fidelity three-dimensional finite element model that incorporates the powerhouse superstructure, submerged concrete substructure, and backfill soil. Modal analysis under four boundary condition scenarios—varying in soil participation and interface contact conditions—systematically quantifies the influence of soil–structure interaction on natural frequencies and mode shapes. Resonance verification against three primary excitation sources—rotational frequency (4.917 Hz), blade passage frequency (24.583 Hz), and rotor–stator interaction frequency (196.667 Hz)—is extended from the first 50 modes to the 400th mode to assess potential high-order resonance risks. Results show that the roof slab, with its large span and low stiffness, exhibits the highest vibration susceptibility. For the rotational frequency, modes 4–12 fall below the 20% code-specified safety margin but rapidly exceed the threshold thereafter. For the blade passage frequency, the separation ratio decreases progressively with increasing mode order within the first 50 modes, and the extended analysis up to the 400th mode shows that the separation ratio remains well above 20% throughout modes 51–400. Consequently, no substantial resonance risk exists for the blade passage frequency within the entire computed range. The rotor–stator interaction frequency remains safely separated with margins exceeding 95%. These findings demonstrate the profound influence of soil–structure interaction and confirm that, despite a decreasing trend in frequency separation at higher orders, the blade passage frequency poses no substantial resonance risk up to the 400th mode. This work provides a rigorous analytical framework for vibration-informed design and optimization of pump foundation systems, with direct implications for the reliability and operational safety of large-scale vertical fluid machinery.

Förderung

  • Open Research Fund Program of State Key Laboratory of Water Disaster Prevention
  • Jiangsu Province Young Scientific and Technological Talent Lifting Project
  • Yangzhou University Qing Lan Project
  • Priority Academic Program Development of Jiangsu Higher Education Institutions
  • College Students’ Innovative Entrepreneurial Training Plan Program

Zitieren

APA

Kuang, K., Du, S., Jia, X., Zhang, B., Li, L., & Jiao, W. (2026). Dynamic Characteristics and Resonance Risk Assessment of a Large-Scale Vertical Pumping Station Structure. Machines, 14(6), 618. https://doi.org/10.3390/machines14060618

Vancouver

Kuang K, Du S, Jia X, Zhang B, Li L, Jiao W. Dynamic Characteristics and Resonance Risk Assessment of a Large-Scale Vertical Pumping Station Structure. Machines. 2026;14(6):618. doi:10.3390/machines14060618

BibTeX
@article{Kuang2026,
  author = {Kuang, Kexin and Du, Sen and Jia, Xuanwen and Zhang, Bowen and Li, Longyu and Jiao, Weixuan},
  title = {Dynamic Characteristics and Resonance Risk Assessment of a Large-Scale Vertical Pumping Station Structure},
  journal = {Machines},
  year = {2026},
  volume = {14},
  number = {6},
  pages = {618},
  doi = {10.3390/machines14060618}
}