EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance Optimization of Savonius VAWTs Using Wind Accelerator and Guiding Rotor House for Enhanced Rooftop Urban Energy Harvesting

Farzad Ghafoorian, Seyed Reza Mirmotahari, Shayan Farajyar, Mehdi Mehrpooya, Mahmood Shafiee

Machines · 10.09.2025 · 13 (9) · 838

DOI: 10.3390/machines13090838 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Machines, online erschienen am 10.09.2025. Verfasst von Farzad Ghafoorian und 4 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Savonius drag-based rotors, a type of vertical-axis wind turbine (VAWT), are well-suited for urban environments—particularly residential rooftops—owing to their compact design and ability to capture wind from all directions. However, their relatively low efficiency and narrow operational range pose significant challenges, such as limited energy output under variable wind conditions and reduced performance across a broad range of tip speed ratios. To address these issues, this study explores flow augmentation using strategically placed deflectors, referred to as Wind Accelerators and Guiding Rotor Houses (WAG-RHs). Four different configurations, including double, triple, oblique, and straight designs, were evaluated against both omni-directional guide vanes (ODGVs) and a conventional rotor. The findings show that the ODGV configuration successfully extends the operational range from a tip speed ratio of 0.5 to 0.6—termed the extended performance point (EPP)—and increases the power coefficient (Cp) by up to 300% compared to the conventional design. Among all setups, the straight WAG-RH configuration proved most effective, not only achieving the EPP but also delivering a 385% and 264.3% increase in local and AVE Cp values, respectively compared to the conventional rotor. It also outperformed the ODGV-equipped rotor by 25%, thanks to its radial and dual-plane arrangement.

Zitieren

APA

Ghafoorian, F., Mirmotahari, S. R., Farajyar, S., Mehrpooya, M., & Shafiee, M. (2025). Performance Optimization of Savonius VAWTs Using Wind Accelerator and Guiding Rotor House for Enhanced Rooftop Urban Energy Harvesting. Machines, 13(9), 838. https://doi.org/10.3390/machines13090838

Vancouver

Ghafoorian F, Mirmotahari SR, Farajyar S, Mehrpooya M, Shafiee M. Performance Optimization of Savonius VAWTs Using Wind Accelerator and Guiding Rotor House for Enhanced Rooftop Urban Energy Harvesting. Machines. 2025;13(9):838. doi:10.3390/machines13090838

BibTeX
@article{Ghafoorian2025,
  author = {Ghafoorian, Farzad and Mirmotahari, Seyed Reza and Farajyar, Shayan and Mehrpooya, Mehdi and Shafiee, Mahmood},
  title = {Performance Optimization of Savonius VAWTs Using Wind Accelerator and Guiding Rotor House for Enhanced Rooftop Urban Energy Harvesting},
  journal = {Machines},
  year = {2025},
  volume = {13},
  number = {9},
  pages = {838},
  doi = {10.3390/machines13090838}
}
Kostenlos starten →