Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control

Francesca Muzio, Lorenzo Mantione, Tomas Garcia-Calva, Lucia Frosini, Daniel Morinigo-Sotelo

Machines · 21.09.2024 · 12 (9) · 662

DOI: 10.3390/machines12090662 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Machines, online erschienen am 21.09.2024. Verfasst von Francesca Muzio und 4 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Electrical Engineering, Research Group ADIRE, ITAP Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotor bar breakage in induction motors is often detected by analysing the signatures in the stator current. However, due to the alteration of the current spectrum, traditional methods may fail when inverter-fed motors operate with closed-loop control using a cascade structure to regulate the speed. In this paper, the potential of zero-sequence voltage analysis to detect this fault is investigated, and a new index to quantify the severity of the fault based on this signal is proposed. Signals from motors operating under different control strategies and signals from motors powered from the mains are considered to verify the robustness of the proposed fault severity index. As a result, in all the analysed conditions the value of the proposed index for the healthy motor is found to be approximately 0.010, while for the faulty machine it is between 0.110 and 0.252.

Förderung

  • Department of Electrical Engineering
  • Research Group ADIRE
  • ITAP Institute
  • University of Valladolid
  • Erasmus+Traineeship grant

Zitieren

APA

Muzio, F., Mantione, L., Garcia-Calva, T., Frosini, L., & Morinigo-Sotelo, D. (2024). Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control. Machines, 12(9), 662. https://doi.org/10.3390/machines12090662

Vancouver

Muzio F, Mantione L, Garcia-Calva T, Frosini L, Morinigo-Sotelo D. Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control. Machines. 2024;12(9):662. doi:10.3390/machines12090662

BibTeX
@article{Muzio2024,
  author = {Muzio, Francesca and Mantione, Lorenzo and Garcia-Calva, Tomas and Frosini, Lucia and Morinigo-Sotelo, Daniel},
  title = {Detection of Broken Bars in Induction Motors Operating with Closed-Loop Speed Control},
  journal = {Machines},
  year = {2024},
  volume = {12},
  number = {9},
  pages = {662},
  doi = {10.3390/machines12090662}
}
Kostenlos starten →