Automated Maximum Torque per Ampere Identification for Synchronous Reluctance Machines with Limited Flux Linkage Information
Machines · 29.01.2024 · 12 (2) · 96
DOI: 10.3390/machines12020096 ↗Kurz gefasst
Fachartikel in der Zeitschrift Machines, online erschienen am 29.01.2024. Verfasst von Shuo Wang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Basic and Commonweal Programme.
Abstract (Originalsprache)
The synchronous reluctance machine is well-known for its highly nonlinear magnetic saturation and cross-saturation characteristics. For high performance and high-efficiency control, the flux-linkage maps and maximum torque per ampere table are of paramount importance. This study proposes a novel automated online searching method for obtaining accurate flux-linkage and maximum torque per ampere Identification. A limited 6 × 2 dq-axis flux-linkage look-up table is acquired by applying symmetric triangle pulses during the self-commissioning stage. Then, three three-dimensional modified linear cubic spline interpolation methods are applied to extend the flux-linkage map. The proposed golden section searching method can be easily implemented to realize higher maximum torque per ampere accuracy after 11 iterations with a standard drive, which is a proven faster solution with reduced memory sources occupied. The proposed algorithm is verified and tested on a 15-kW SynRM drive. Furthermore, the iterative and execution times are evaluated.
Förderung
- Zhejiang Basic and Commonweal Programme
Zitieren
APA
Wang, S., Varvolik, V., Bao, Y., Aboelhassan, A., Degano, M., Buticchi, G., & Zhang, H. (2024). Automated Maximum Torque per Ampere Identification for Synchronous Reluctance Machines with Limited Flux Linkage Information. Machines, 12(2), 96. https://doi.org/10.3390/machines12020096
Vancouver
Wang S, Varvolik V, Bao Y, Aboelhassan A, Degano M, Buticchi G, et al. Automated Maximum Torque per Ampere Identification for Synchronous Reluctance Machines with Limited Flux Linkage Information. Machines. 2024;12(2):96. doi:10.3390/machines12020096
BibTeX
@article{Wang2024,
author = {Wang, Shuo and Varvolik, Vasyl and Bao, Yuli and Aboelhassan, Ahmed and Degano, Michele and Buticchi, Giampaolo and Zhang, He},
title = {Automated Maximum Torque per Ampere Identification for Synchronous Reluctance Machines with Limited Flux Linkage Information},
journal = {Machines},
year = {2024},
volume = {12},
number = {2},
pages = {96},
doi = {10.3390/machines12020096}
}
EUVIMED