Wind/Wave Testing of a 1:70-Scale Performance-Matched Model of the IEA Wind 15 MW Reference Wind Turbine with Real-Time ROSCO Control and Floating Feedback

Matthew Fowler, Eben Lenfest, Anthony Viselli, Andrew Goupee, Richard Kimball, Roger Bergua, Lu Wang, Daniel Zalkind, Alan Wright, Amy Robertson

Machines · 28.08.2023 · 11 (9) · 865

DOI: 10.3390/machines11090865 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Machines, online erschienen am 28.08.2023. Verfasst von Matthew Fowler und 9 weiteren Autor:innen. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Maine for the U.S. Department of Energy (DOE), U.S. Department of Energy Advanced Research Projects Agency-Energy (ARPA-E), National Renewable Energy Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Experimental results from the Floating Offshore-wind and Controls Advanced Laboratory (FOCAL) experimental program, which tested a performance-matched model of the IEA Wind 15 MW Reference Turbine on a 1:70 scale floating semisubmersible platform, are compared with OpenFAST simulations. Four experimental campaigns were performed, and data from the fourth campaign, which focused on wind and wave testing of the scaled floating wind turbine system, are considered. Simulations of wave-only, wind-only, and wind/wave environments are performed in OpenFAST, and results for key metrics are compared with the experiment. Performance of the real-time Reference OpenSource COntroller (ROSCO) in above-rated wind conditions, including the effects of the floating feedback loop, are investigated. Results show good agreement in mean values for key metrics, and hydrodynamic effects are matched well. Differences in the surge resonant behavior of the platform are identified and discussed. The effect of the controller and floating feedback loop is evident in both the experiment and OpenFAST, showing significant reduction in platform pitch response and tower base bending load near the platform pitch natural frequency.

Förderung

  • University of Maine for the U.S. Department of Energy (DOE)
  • U.S. Department of Energy Advanced Research Projects Agency-Energy (ARPA-E)
  • National Renewable Energy Laboratory

Zitieren

APA

Fowler, M., Lenfest, E., Viselli, A., Goupee, A., Kimball, R., Bergua, R., Wang, L., Zalkind, D., Wright, A., & Robertson, A. (2023). Wind/Wave Testing of a 1:70-Scale Performance-Matched Model of the IEA Wind 15 MW Reference Wind Turbine with Real-Time ROSCO Control and Floating Feedback. Machines, 11(9), 865. https://doi.org/10.3390/machines11090865

Vancouver

Fowler M, Lenfest E, Viselli A, Goupee A, Kimball R, Bergua R, et al. Wind/Wave Testing of a 1:70-Scale Performance-Matched Model of the IEA Wind 15 MW Reference Wind Turbine with Real-Time ROSCO Control and Floating Feedback. Machines. 2023;11(9):865. doi:10.3390/machines11090865

BibTeX
@article{Fowler2023,
  author = {Fowler, Matthew and Lenfest, Eben and Viselli, Anthony and Goupee, Andrew and Kimball, Richard and Bergua, Roger and Wang, Lu and Zalkind, Daniel and Wright, Alan and Robertson, Amy},
  title = {Wind/Wave Testing of a 1:70-Scale Performance-Matched Model of the IEA Wind 15 MW Reference Wind Turbine with Real-Time ROSCO Control and Floating Feedback},
  journal = {Machines},
  year = {2023},
  volume = {11},
  number = {9},
  pages = {865},
  doi = {10.3390/machines11090865}
}
Kostenlos starten →