MicroCT-Based Degradation-Induced Sub-Voxel Porosity Mapping: A Case Study of a PHBV/PLGA/TCP Composite Scaffold
Materials · 11.11.2026 · 19 (22) · 4784
DOI: 10.3390/ma19224784 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 11.11.2026. Verfasst von Karol Szlązak. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Centre for Research and Development.
Abstract (Originalsprache)
Microcomputed tomography (microCT) enables non-destructive 3D imaging, but conventional segmentation cannot resolve objects smaller than a voxel. This study presents a microCT-based method that maps degradation-induced sub-voxel porosity by converting voxel-specific X-ray attenuation changes between registered pre- and post-degradation datasets into porosity estimates. The method also accounts for other degradation-induced physical and chemical changes that affect X-ray attenuation; however, their contributions cannot be directly separated from the estimated change in porosity. The method was demonstrated on poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV), Poly(lactic-co-glycolic acid) (PLGA) and tricalcium phosphate (TCP) scaffolds. Specimens were scanned before and after degradation using identical acquisition and reconstruction settings, and datasets were 3D-registered. The estimated effective sub-voxel porosity increase was 8.33 ± 0.63%, versus a gravimetric mass loss of 7.89 ± 0.82%. SEM showed a pore area fraction of 7.64 ± 0.23% and a mean equivalent pore diameter of 1.79 ± 1.15 μm, below the 5.5 μm voxel size. Maps revealed spatially heterogeneous degradation-related changes. The consistency between the microCT-derived estimate and the complementary evidence from gravimetry and SEM provides indirect validation of the interpretation of the measured X-ray attenuation changes in terms of effective sub-voxel porosity.
Förderung
- National Centre for Research and Development
Zitieren
APA
Szlązak, K. (2026). MicroCT-Based Degradation-Induced Sub-Voxel Porosity Mapping: A Case Study of a PHBV/PLGA/TCP Composite Scaffold. Materials, 19(22), 4784. https://doi.org/10.3390/ma19224784
Vancouver
Szlązak K. MicroCT-Based Degradation-Induced Sub-Voxel Porosity Mapping: A Case Study of a PHBV/PLGA/TCP Composite Scaffold. Materials. 2026;19(22):4784. doi:10.3390/ma19224784
BibTeX
@article{Szlzak2026,
author = {Szlązak, Karol},
title = {MicroCT-Based Degradation-Induced Sub-Voxel Porosity Mapping: A Case Study of a PHBV/PLGA/TCP Composite Scaffold},
journal = {Materials},
year = {2026},
volume = {19},
number = {22},
pages = {4784},
doi = {10.3390/ma19224784}
}
EUVIMED