Did Material Properties Contribute to the 1284 Collapse of Beauvais Cathedral? A Comparative Assessment of Stone Masonry, Mortar Behaviour and Structural Vulnerability

Rubén Rodríguez Elizalde iD

Materials · 01.11.2026 · 19 (21) · 4659

DOI: 10.3390/ma19214659 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 01.11.2026. Verfasst von Rubén Rodríguez Elizalde. Beteiligte Einrichtung: Higher Polytechnic School of Technology and Science, Camilo José Cela University, C/Castillo de Alarcón, 49, Urbanización Villafranca del Castillo, V…. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The partial collapse of the choir vaults of Beauvais Cathedral in 1284 has been explained through structural and constructional hypotheses, but the role of the materials has never been tested against laboratory data. The objective of this study is to quantify, with a transparent probabilistic framework, whether the properties of the stone and the lime mortar could have contributed to the collapse. Four material-dependent mechanisms are assessed—crushing, differential shortening between coursed masonry and monolithic shafts, time-dependent deformation under eccentric load, and the dependence of the buttressing on stone strength—using a traceable database that combines published tests on chalk representative of the Beauvais stone, data on air lime mortars, the documented geometry of the choir and field measurements of the masonry bond. Uncertainty is propagated through 105 Monte Carlo simulations and expressed as central and characteristic safety factors and reliability indices. The central safety factor of the choir piers against crushing is 4.3 for the dry stone and 2.5 for the saturated stone, far below the margin implicit in earlier analyses. Coursed masonry shortens about 4 to 6 times more than a monolithic shaft in the long term, which, under strain compatibility, concentrates stresses of 2.5 to 5 times the mean value in the shafts. Creep-induced amplification is small in a laterally braced pier but becomes critical if lateral restraint is lost. The results indicate that the material did not cause the collapse through lack of strength but is compatible with a material contribution through its deformability and its sensitivity to water.

Schlagwörter

Stichwörter der Autor:innen

Beauvais CathedralMonte Carlo analysischalkconservationcreepdifferential shorteninggothic masonrylime mortarreliability indexstructural collapse

Autor:innen und Institutionen

  • Higher Polytechnic School of Technology and Science, Camilo José Cela University, C/Castillo de Alarcón, 49, Urbanización Villafranca del Castillo, Villanueva de la Cañada, 28692 Madrid, Spain.

ORCID-Profile: Rubén Rodríguez Elizalde

Zitieren

APA

Elizalde, R. R. (2026). Did Material Properties Contribute to the 1284 Collapse of Beauvais Cathedral? A Comparative Assessment of Stone Masonry, Mortar Behaviour and Structural Vulnerability. Materials, 19(21), 4659. https://doi.org/10.3390/ma19214659

Vancouver

Elizalde RR. Did Material Properties Contribute to the 1284 Collapse of Beauvais Cathedral? A Comparative Assessment of Stone Masonry, Mortar Behaviour and Structural Vulnerability. Materials. 2026;19(21):4659. doi:10.3390/ma19214659

BibTeX
@article{Elizalde2026,
  author = {Elizalde, Rubén Rodríguez},
  title = {Did Material Properties Contribute to the 1284 Collapse of Beauvais Cathedral? A Comparative Assessment of Stone Masonry, Mortar Behaviour and Structural Vulnerability},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {4659},
  doi = {10.3390/ma19214659}
}
Kostenlos starten →