EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Method-Dependent Bond Strength of Thin-Bed Mortars with Coded Modifiers on Autoclaved Aerated Concrete

Beata Łaźniewska-Piekarczyk iD, Adam Piekarczyk iD

Materials · 31.10.2026 · 19 (21) · 4629

DOI: 10.3390/ma19214629 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 31.10.2026. Verfasst von Beata Łaźniewska-Piekarczyk und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Building Processes and Building Physics, Faculty of Civil Engineering, Silesian University of Technology, Akademicka 5, 44-100 Gliwice,…. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Silesian University of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study reanalyzes the tensile bond of white-cement thin-bed mortar joints with a measured thickness of 1 mm in autoclaved aerated concrete (AAC), using axial core tension, the EN 1052-5 bond-wrench method, and companion hardened-mortar tests. Individual observations are summarized descriptively alongside exploratory formulation-mean models. For 94 mm cores, mixture C (0.229 wt.%) had the highest axial mean (0.528 ± 0.081 MPa; n = 4), versus 0.378 ± 0.065 MPa for the reference (n = 5). Mixture A had a low axial mean (0.139 ± 0.123 MPa) but the largest bond-wrench mean (0.351 MPa), demonstrating method-dependent rankings. The available product card for the C-coded powder describes it only as a re-dispersible synthetic-resin powder; the remaining modifiers are known only from broad recorded labels. Water carried by liquid O was included in the total mixing-water dose of 5.75 L per 25 kg of dry base mortar; however, its separate amount was not recorded. The 94 mm bonded area was 2.92 times that of the preliminary 55 mm cores, whose high scatter and unresolved data inconsistency preclude comparison. One wrench assembly was tested per mixture; incomplete fresh-state and conditioning records constrain inference. The study provides a method-aware comparison for this specific thin AAC joint without claiming novelty with respect to AAC bond research.

Schlagwörter

Stichwörter der Autor:innen

1 mm bed jointadmixture dosageautoclaved aerated concretebond-wrench testdirect axial tensionmasonry bondstress distributionthin-bed mortar

Autor:innen und Institutionen

  • Department of Building Processes and Building Physics, Faculty of Civil Engineering, Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland.
  • Department of Building Structures, Faculty of Civil Engineering, Silesian University of Technology, Akademicka 5, 44-100 Gliwice, Poland.

ORCID-Profile: Beata Łaźniewska-Piekarczyk, Adam Piekarczyk

Förderung

  • Silesian University of Technology

Zitieren

APA

Łaźniewska-Piekarczyk, B., & Piekarczyk, A. (2026). Method-Dependent Bond Strength of Thin-Bed Mortars with Coded Modifiers on Autoclaved Aerated Concrete. Materials, 19(21), 4629. https://doi.org/10.3390/ma19214629

Vancouver

Łaźniewska-Piekarczyk B, Piekarczyk A. Method-Dependent Bond Strength of Thin-Bed Mortars with Coded Modifiers on Autoclaved Aerated Concrete. Materials. 2026;19(21):4629. doi:10.3390/ma19214629

BibTeX
@article{aniewskaPiekarczyk2026,
  author = {Łaźniewska-Piekarczyk, Beata and Piekarczyk, Adam},
  title = {Method-Dependent Bond Strength of Thin-Bed Mortars with Coded Modifiers on Autoclaved Aerated Concrete},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {21},
  pages = {4629},
  doi = {10.3390/ma19214629}
}
Kostenlos starten →