Fachartikel in der Zeitschrift Materials, online erschienen am 29.10.2026. Verfasst von Yixuan Zhao und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325000, China. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The author confirms that no explanations are needed for the colors in the picture, the Central Government-Guided Local Science and Technology Development Fund Projects.
Abstract (Originalsprache)
This study investigates the electrical response of concrete containing copper-coated steel fibers (CCSFs), with particular attention to the effects of voltage, which are insufficiently considered in conventional resistivity measurements. An optimized resistivity measurement method was developed to systematically evaluate the effects of CCSF volume fraction, water-to-cement ratio, temperature, and applied voltage on the electrical resistivity of CCSF concrete. The results showed that increasing the CCSF volume fraction from 0% to 3%, the temperature from −20 °C to 80 °C, and the applied voltage from 10 V to 60 V reduced the electrical resistivity by 87.18%, 92.99%, and 80.02%, respectively, whereas increasing the water-to-cement ratio from 0.35 to 0.55 resulted in a smaller reduction of 26.74%. The CCSF content and water-to-cement ratio primarily affected the baseline resistivity, while having limited effects on the normalized temperature response. The applied voltage also affected the absolute resistivity values, and the sensitivity of resistivity to applied voltage increased with increasing CCSF volume fraction. These findings indicate that applied voltage is a key parameter affecting both the electrical response of CCSF concrete and the comparability of resistivity measurements. This study provides experimental evidence for optimizing resistivity testing conditions and evaluating conductive concrete performance under complex environments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Civil Engineering and Architecture, Wenzhou University, Wenzhou 325000, China.
- Key Laboratory of Engineering and Technology for Tideland Reclamation and Life-Cycle Intelligent Monitoring of Zhejiang Province, Wenzhou 325035, China.
- Wenzhou Engineering Technical Research Center on Building Energy Conservation and Emission Reduction & Disaster Prevention and Mitigation, Wenzhou 325000, China.
- College of Architecture and Energy Engineering, Wenzhou University of Technology, Wenzhou 325035, China.
Förderung
- The author confirms that no explanations are needed for the colors in the picture
- the Central Government-Guided Local Science and Technology Development Fund Projects
Zitieren
APA
Zhao, Y., Sun, F., Wang, Z., & Zhu, Y. (2026). Effect of Copper-Coated Steel Fibers on the Electrical Conductivity of Concrete Under Multiple Influencing Factors. Materials, 19(21), 4587. https://doi.org/10.3390/ma19214587
Vancouver
Zhao Y, Sun F, Wang Z, Zhu Y. Effect of Copper-Coated Steel Fibers on the Electrical Conductivity of Concrete Under Multiple Influencing Factors. Materials. 2026;19(21):4587. doi:10.3390/ma19214587
BibTeX
@article{Zhao2026,
author = {Zhao, Yixuan and Sun, Fuxue and Wang, Zhongkun and Zhu, Yunhui},
title = {Effect of Copper-Coated Steel Fibers on the Electrical Conductivity of Concrete Under Multiple Influencing Factors},
journal = {Materials},
year = {2026},
volume = {19},
number = {21},
pages = {4587},
doi = {10.3390/ma19214587}
}
EUVIMED