Reference-Based Layer Echo Suppression for Ultrasonic Evaluation of Thick Pultruded CFRP Composites
Materials · 29.10.2026 · 19 (21) · 4566
DOI: 10.3390/ma19214566 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 29.10.2026. Verfasst von Hun-Hee Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Doosan Enerbility, Changwon-si 51711, Republic of Korea. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Trade, Industry and Energy.
Abstract (Originalsprache)
Pultruded carbon-fiber-reinforced polymer (CFRP) composites are increasingly used in large wind turbine blades, but ultrasonic evaluation of thick pultruded structures is complicated by repetitive layer reflections and prolonged transducer ringing. This study proposes a reference-based Layer Echo Suppression Method (LESM) to suppress deterministic structural responses that can mask internal defect echoes, thereby improving the visibility and identification of damage-related reflectors in thick CFRP components. Ultrasonic A-scan signals were acquired from sound and defect regions of a 100-mm-thick pultruded CFRP specimen containing an artificial defect at approximately 50 mm using a 0.5 MHz single-element contact transducer. LESM combines cross-correlation-based registration, independent wavelet denoising, reference-based Hilbert-envelope differencing, and positive-residual weighting of the denoised defect signal. The normalized cross-correlation coefficient between the reference and defect signals was 0.9941. DBR-based evaluation selected Sym5 at decomposition level 5. The final LESM signal yielded a defect-to-background ratio (DBR) of 34.82 dB, compared with 14.14 dB for the raw signal, an improvement of 20.68 dB. The defect-related waveform near 50 mm was retained while surrounding layer echoes and ringing were substantially reduced. By enhancing localized defect reflections without requiring additional ultrasonic hardware, LESM can support the identification of internal planar damage-like discontinuities in thick CFRP components using conventional pulse-echo measurements. These results demonstrate the proof-of-concept feasibility of the proposed method under the examined condition.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Doosan Enerbility, Changwon-si 51711, Republic of Korea.
- Department of Smart Mechanical Engineering, Dongyang University, Yeongju-si 36040, Republic of Korea.
ORCID-Profile: Yun-Taek Yeom
Förderung
- Ministry of Trade, Industry and Energy
Zitieren
APA
Kim, H. H., Kim, B. J., & Yeom, Y. T. (2026). Reference-Based Layer Echo Suppression for Ultrasonic Evaluation of Thick Pultruded CFRP Composites. Materials, 19(21), 4566. https://doi.org/10.3390/ma19214566
Vancouver
Kim HH, Kim BJ, Yeom YT. Reference-Based Layer Echo Suppression for Ultrasonic Evaluation of Thick Pultruded CFRP Composites. Materials. 2026;19(21):4566. doi:10.3390/ma19214566
BibTeX
@article{Kim2026,
author = {Kim, Hun-Hee and Kim, Bong-Ju and Yeom, Yun-Taek},
title = {Reference-Based Layer Echo Suppression for Ultrasonic Evaluation of Thick Pultruded CFRP Composites},
journal = {Materials},
year = {2026},
volume = {19},
number = {21},
pages = {4566},
doi = {10.3390/ma19214566}
}