Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study
Materials · 27.10.2026 · 19 (21) · 4516
DOI: 10.3390/ma19214516 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 27.10.2026. Verfasst von Zhu Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Materials for Advanced Nuclear Energy & School of Materials Science and Engineering, Shanghai University, Shanghai 200444, Ch…. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Ce:GAGG linear scintillator detectors are promising for high-resolution radiation imaging, but signal sharing near pixel boundaries can affect position resolution. A Geant4 model of a 16 × 1 array was used to assess the lateral pixel dimension (PT), reflector thickness (REF), reflector material, metal interlayer and anti-scatter grid (ASG). The Gaussian-equivalent full width at half maximum (FWHM) of the reconstructed-position distribution and the spatial frequency at 50% modulation transfer (MTF50) were evaluated at central and boundary irradiation positions. PT = 1.0 mm, REF = 0.3 mm and MgO gave a favorable balance between central and boundary responses; the metal interlayer had little influence. A W ASG with 0.60 mm bars and a height of 5.0 mm was selected by comparing total and neighboring-channel energy-deposition tallies in a scattering-phantom geometry. Relative to the reference configuration, the phase-integrated adjacent-channel optical-response fraction decreased from 13.66% to 1.53%, the slanted-edge 10–90% width decreased from 2.951 to 1.876 mm, and the imaging MTF50 point estimate increased from 0.163 to 0.256 cycles mm−1. The integrated recorded optical-photon count decreased by 47.2%. In an ASG-free optical comparison, bar-pattern modulation increased from 0.361 to 0.668. The numerical results apply to the specified simulation and scoring conditions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Materials for Advanced Nuclear Energy & School of Materials Science and Engineering, Shanghai University, Shanghai 200444, China.
- Zhejiang Institute of Advanced Materials, Shanghai University, Jiaxing 314113, China.
- Shanghai Engineering Research Center for Integrated Circuits and Advanced Display Materials, Shanghai University, Shanghai 200444, China.
ORCID-Profile: Yanggang Jia
Förderung
- National Key R&D Program of China
- National Natural Science Foundation of China
Zitieren
APA
Liu, Z., Jia, Y., Guan, Z., Wang, X., Cao, M., Huang, H., Wang, L., & Huang, J. (2026). Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study. Materials, 19(21), 4516. https://doi.org/10.3390/ma19214516
Vancouver
Liu Z, Jia Y, Guan Z, Wang X, Cao M, Huang H, et al. Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study. Materials. 2026;19(21):4516. doi:10.3390/ma19214516
BibTeX
@article{Liu2026,
author = {Liu, Zhu and Jia, Yanggang and Guan, Zhaoran and Wang, Xinya and Cao, Meng and Huang, Haofei and Wang, Linjun and Huang, Jian},
title = {Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study},
journal = {Materials},
year = {2026},
volume = {19},
number = {21},
pages = {4516},
doi = {10.3390/ma19214516}
}
EUVIMED