Comparative Flammability and SEM–EDS Characterization of Contemporary, Aged and Charred Oak Wood from Historic Timber Structures
Materials · 07.08.2026 · 19 (16) · 3365
DOI: 10.3390/ma19163365 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 07.08.2026. Verfasst von Andrzej Jurecki und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Forestry and Wood Technology, Poznań University of Life Sciences, Wojska Polskiego 28, 60-637 Poznań, Poland. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Polish Minister of Science and Higher Education.
Abstract (Originalsprache)
Historic timber combines structural function with heritage value, yet its fire behaviour is inferred from contemporary wood data. This study provides an integrated, condition-based assessment of contemporary oak (Quercus robur L.) and historic oak from a nineteenth-century half-timbered building in Swołowo, Poland. Mass loss calorimetry (MLC) at 35 and 50 kW/m2 was combined with scanning electron microscopy (SEM) and SEM coupled with energy-dispersive X-ray spectroscopy (SEM–EDS). The aim was to determine whether surface preservation state explains differences between ignition sensitivity and cumulative heat release. Historic oak ignited earlier than contemporary oak, especially when the tested surface was degraded; at 50 kW/m2, time to ignition decreased from 25.33 s for contemporary oak to 18 s for non-degraded historic oak and 5.33 s for degraded historic oak. However, total heat release was lower for historic variants and final mass loss remained comparable. SEM showed roughness, fibrillation, delamination, fractured cell-wall edges and secondary porosity in aged and charred zones. SEM–EDS indicated C- and O-dominated preserved areas, whereas degraded and charred surfaces were enriched in inorganic elements. The results show that ignition propensity and total fire contribution should be evaluated separately, and that condition rather than age alone is critical for historic oak assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Forestry and Wood Technology, Poznań University of Life Sciences, Wojska Polskiego 28, 60-637 Poznań, Poland.
- Faculty of Civil Engineering and Architecture, Lublin University of Technology, 20-618 Lublin, Poland.
ORCID-Profile: Wojciech Grześkowiak, Beata Klimek, Marek Wieruszewski
Förderung
- Polish Minister of Science and Higher Education
Zitieren
APA
Jurecki, A., Grześkowiak, W., Klimek, B., & Wieruszewski, M. (2026). Comparative Flammability and SEM–EDS Characterization of Contemporary, Aged and Charred Oak Wood from Historic Timber Structures. Materials, 19(16), 3365. https://doi.org/10.3390/ma19163365
Vancouver
Jurecki A, Grześkowiak W, Klimek B, Wieruszewski M. Comparative Flammability and SEM–EDS Characterization of Contemporary, Aged and Charred Oak Wood from Historic Timber Structures. Materials. 2026;19(16):3365. doi:10.3390/ma19163365
BibTeX
@article{Jurecki2026,
author = {Jurecki, Andrzej and Grześkowiak, Wojciech and Klimek, Beata and Wieruszewski, Marek},
title = {Comparative Flammability and SEM–EDS Characterization of Contemporary, Aged and Charred Oak Wood from Historic Timber Structures},
journal = {Materials},
year = {2026},
volume = {19},
number = {16},
pages = {3365},
doi = {10.3390/ma19163365}
}
EUVIMED