EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry

Marko Kršulja iD, Lovro Liverić iD, Damir Karabaić iD, Vedrana Špada iD

Materials · 27.07.2026 · 19 (15) · 3200

DOI: 10.3390/ma19153200 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 27.07.2026. Verfasst von Marko Kršulja und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering, Juraj Dobrila University of Pula, Negrijeva 6, 52100 Pula, Croatia. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Juraj Dobrila University of Pula.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A CT-80 coiled tubing fractured at the gooseneck during retrieval after a 2.5 h treatment with 15% HCl under high-temperature bottom-hole conditions (196 °C). The failure was investigated by dimensional measurements, metallography, Vickers microhardness testing, SEM/EDS, and FT-IR spectroscopy. Pronounced corrosion asymmetry was observed. Cumulative external wall loss reached 1.196 mm, compared with 0.292 mm on the inner wall, while the wall loss attributed to the final operation was approximately twelve times greater externally than internally. These findings suggest two different exposure histories: predominantly uniform attack of the outer wall during backflow of spent, inhibitor-depleted acid, and localized pitting of the inner wall under incomplete inhibitor coverage. EDS mapping identified Sb-rich deposits around inner-wall pits. In combination with the relevant literature, this distribution is consistent with a possible Sb–Fe galvanic effect that may have promoted local anodic dissolution, although galvanic coupling was not measured directly. The FT-IR spectra were consistent with iron oxides/oxyhydroxides, carbonate-containing scale, sulfate-bearing products on the outer surface, and thin organic residues rather than a continuous inhibitor film. Microhardness increased from 229 HV1 in the new tubing to 243.4 HV1 at the fracture location; this increase may reflect limited hydrogen uptake together with service-induced strain hardening or residual stresses. Fractography showed necking and dimpled microvoid coalescence, supporting a predominantly ductile overload mechanism in the corrosion-thinned section. A limited contribution of hydrogen to ductility loss cannot be excluded because the hydrogen content was not quantified.

Schlagwörter

Stichwörter der Autor:innen

HTBH acidizingcoiled tubing failurecorrosion asymmetryductile fracturehydrogen embrittlementinhibitor depletionpitting corrosion

Autor:innen und Institutionen

  • Faculty of Engineering, Juraj Dobrila University of Pula, Negrijeva 6, 52100 Pula, Croatia.
  • Metris Research Center, Istrian University of Applied Sciences, Preradovićeva 9D, 52100 Pula, Croatia.

ORCID-Profile: Marko Kršulja, Lovro Liverić, Damir Karabaić, Vedrana Špada

Förderung

  • Juraj Dobrila University of Pula

Zitieren

APA

Kršulja, M., Liverić, L., Karabaić, D., & Špada, V. (2026). Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry. Materials, 19(15), 3200. https://doi.org/10.3390/ma19153200

Vancouver

Kršulja M, Liverić L, Karabaić D, Špada V. Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry. Materials. 2026;19(15):3200. doi:10.3390/ma19153200

BibTeX
@article{Krulja2026,
  author = {Kršulja, Marko and Liverić, Lovro and Karabaić, Damir and Špada, Vedrana},
  title = {Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {15},
  pages = {3200},
  doi = {10.3390/ma19153200}
}
Kostenlos starten →