Mechanical, Durability and Microstructural Performance of OPC–GGBFS–FGD Gypsum Ternary Concrete: Identification of an Operational Sulfate Activation Threshold
Materials · 09.07.2026 · 19 (14) · 2962
DOI: 10.3390/ma19142962 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 09.07.2026. Verfasst von Anand Bhatt und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil Engineering, National Institute of Technology Jamshedpur, Jamshedpur 831014, India. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Széchenyi István University.
Abstract (Originalsprache)
Ordinary Portland cement (OPC) production contributes approximately 7–8% of global anthropogenic CO2 emissions, driving urgent demand for clinker-efficient binders utilizing industrial by-products. Flue gas desulfurization (FGD) gypsum and ground granulated blast-furnace slag (GGBFS) represent underutilized industrial by-products with documented potential as supplementary cementitious materials. This study investigates the mechanical, durability and microstructural performance of OPC–GGBFS–FGD gypsum ternary concrete mixtures incorporating untreated flue gas desulfurization (FGD) gypsum at 0–20% of total binder mass and ground granulated blast-furnace slag (GGBFS) at 25–50% of total binder mass in M30 structural concrete (w/b = 0.45). Compressive, split tensile and flexural strengths were evaluated at 7–90 days alongside rapid chloride penetration (RCPT), water absorption, strength efficiency index (SEI) and SEM–EDX analyses. Binary GGBFS replacement progressively enhanced long-term compressive strength, with T35F0 attaining 55.6 N/mm2 at 90 days (+33.7% relative to the OPC control). Moderate FGD gypsum contents (5–10%) further enhanced overall performance. Among all mixtures, T50F10 exhibited the best overall performance on the mechanical and durability indicators evaluated, achieving 54.2 N/mm2 compressive strength at 90 days together with a rapid chloride permeability value of 410 C, corresponding to ‘Very Low’ chloride ion penetrability. Beyond 10% FGD gypsum, progressive multi-parameter deterioration was observed, and mixtures containing 20% FGD gypsum failed to meet the M30 design requirement at 28 days. SEM–EDX confirmed that optimum sulfate activation produced a dense C–(A)–S–H-rich matrix, while excess sulfate caused matrix disruption. The findings establish 10% FGD gypsum by total binder mass as the optimum sulfate activation threshold for the investigated GGBFS and FGD gypsum sources at w/b = 0.45, and demonstrate the potential of untreated industrial FGD gypsum to produce durable, low-clinker structural concrete.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Civil Engineering, National Institute of Technology Jamshedpur, Jamshedpur 831014, India.
- Department of Civil Engineering, Nirma University, Ahmedabad 382481, India.
- Department of Civil Engineering, Graphic Era Deemed to be University, Dehradun 248002, India.
- Department of Structural Engineering and Geotechnics, Széchenyi István University, Egyetem Tér 1, 9026 Győr, Hungary.
ORCID-Profile: Anand Bhatt, Sanjay Kumar, Prahlad Prasad, Anasuya Sahu, Pramod Kumar, Ardalan B Hussein
Förderung
- Széchenyi István University
Zitieren
APA
Bhatt, A., Kumar, S., Prasad, P., Sahu, A., Kumar, P., & Hussein, A. B. (2026). Mechanical, Durability and Microstructural Performance of OPC–GGBFS–FGD Gypsum Ternary Concrete: Identification of an Operational Sulfate Activation Threshold. Materials, 19(14), 2962. https://doi.org/10.3390/ma19142962
Vancouver
Bhatt A, Kumar S, Prasad P, Sahu A, Kumar P, Hussein AB. Mechanical, Durability and Microstructural Performance of OPC–GGBFS–FGD Gypsum Ternary Concrete: Identification of an Operational Sulfate Activation Threshold. Materials. 2026;19(14):2962. doi:10.3390/ma19142962
BibTeX
@article{Bhatt2026,
author = {Bhatt, Anand and Kumar, Sanjay and Prasad, Prahlad and Sahu, Anasuya and Kumar, Pramod and Hussein, Ardalan B},
title = {Mechanical, Durability and Microstructural Performance of OPC–GGBFS–FGD Gypsum Ternary Concrete: Identification of an Operational Sulfate Activation Threshold},
journal = {Materials},
year = {2026},
volume = {19},
number = {14},
pages = {2962},
doi = {10.3390/ma19142962}
}
EUVIMED