EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Determining the Impedance of an Eddy Current Probe Placed over a Defect-Free Conductive Cylinder with a Centred Circular Hole

Grzegorz Tytko iD, Yike Xiang, Yao Luo

Materials · 24.06.2026 · 19 (13) · 2718

DOI: 10.3390/ma19132718 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 24.06.2026. Verfasst von Grzegorz Tytko und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Automatic Control, Electronics and Computer Science, Silesian University of Technology, Akademicka 16, 44-100 Gliwice, Poland. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The measurement of a probe impedance performed during eddy current inspections enables detection of flaws in electrically conductive materials. A correct interpretation of the measured impedance values constitutes a key aspect that determines the effectiveness of the inspections, and for this purpose, mathematical models are employed. Such models, which are becoming more and more frequently an integral part of eddy current measurement systems, enable carrying out the calculation of the probe impedance, through depicting the measurements being performed. What offer the shortest calculation time while maintaining high accuracy are analytical solutions. In this paper, to the best of the authors’ knowledge, this is the first time an analytical model of an eddy current probe placed over a small diameter cylinder containing a hole has been presented. The final formulas were obtained using the truncated region eigenfunction expansion (TREE) method, and then implemented in Matlab. The calculated values of the probe resistance and reactance were compared with the measurement results obtained for cylinders with a through defect. The tests were conducted on components made of several conductive materials with different geometric dimensions. The measurement error in all of the tests was small, i.e., it did not exceed 3% across the entire frequency range. The proposed solution can be used in defectoscopy for eddy current testing of tubes, pucks, washers, and any cylindrical elements.

Schlagwörter

Stichwörter der Autor:innen

coil impedancedefect detectiondefectoscopyeddy current probenon-destructive testing

Autor:innen und Institutionen

  • Faculty of Automatic Control, Electronics and Computer Science, Silesian University of Technology, Akademicka 16, 44-100 Gliwice, Poland.
  • State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.
  • School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.

ORCID-Profile: Grzegorz Tytko

Zitieren

APA

Tytko, G., Xiang, Y., & Luo, Y. (2026). Determining the Impedance of an Eddy Current Probe Placed over a Defect-Free Conductive Cylinder with a Centred Circular Hole. Materials, 19(13), 2718. https://doi.org/10.3390/ma19132718

Vancouver

Tytko G, Xiang Y, Luo Y. Determining the Impedance of an Eddy Current Probe Placed over a Defect-Free Conductive Cylinder with a Centred Circular Hole. Materials. 2026;19(13):2718. doi:10.3390/ma19132718

BibTeX
@article{Tytko2026,
  author = {Tytko, Grzegorz and Xiang, Yike and Luo, Yao},
  title = {Determining the Impedance of an Eddy Current Probe Placed over a Defect-Free Conductive Cylinder with a Centred Circular Hole},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {13},
  pages = {2718},
  doi = {10.3390/ma19132718}
}
Kostenlos starten →