EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Fiber Contamination from Different Microapplicators in Universal Adhesive Systems: A Pilot In Vitro Study

Flavius-Alexandru Sinitean iD, Luminița-Maria Nica iD, Laura-Elena Cîrligeriu, Anca Jivănescu iD

Materials · 13.06.2026 · 19 (12) · 2562

DOI: 10.3390/ma19122562 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 13.06.2026. Verfasst von Flavius-Alexandru Sinitean und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry and Endodontics, TADERP Research Center, Faculty of Dentistry, "Victor Babeș" University of Medicine and Pharmacy…. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: “Victor Babeș” University of Medicine and Pharmacy Timișoara.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fiber contamination originating from disposable dental microapplicators has received limited attention despite its potential influence on adhesive procedures. The aim of this pilot in vitro study was to evaluate fiber-like structure release associated with different microapplicator types during the application of universal adhesive systems. Three universal adhesives (Clearfil Universal Bond Quick, Gluma Universal, and G-Premio BOND) and five microapplicator types (X-Slim, Clinique, Prima, Single TIM, and ZerofloX silicone-bristle microapplicators) were evaluated. A total of 75 adhesive applications were performed on standardized sandblasted glass substrates under controlled laboratory conditions. Adhesives were actively applied for 10 s, and fiber-like structures were quantified microscopically using ImageJ software. Statistical analysis included descriptive statistics, two-way ANOVA, and Tukey post hoc testing (α = 0.05). Significant differences were observed among microapplicator types. X-Slim applicators produced the highest fiber counts, whereas Single TIM applicators demonstrated substantially lower values. No detectable fiber-like structures were observed in specimens treated with the ZerofloX silicone-bristle microapplicator. Adhesive system type showed a comparatively smaller influence on fiber counts than microapplicator design. Within the limitations of this pilot in vitro study, microapplicator type appeared to be the primary factor influencing visible fiber contamination during adhesive application. Further studies are required to determine whether the contamination patterns observed influence adhesive performance under clinically relevant conditions.

Schlagwörter

Stichwörter der Autor:innen

active applicationadhesive dentistryfiber-like contaminationin vitro studymicroapplicatorsuniversal adhesive

Autor:innen und Institutionen

  • Department of Restorative Dentistry and Endodontics, TADERP Research Center, Faculty of Dentistry, "Victor Babeș" University of Medicine and Pharmacy, Eftimie Murgu Square 2, 300041 Timișoara, Romania.
  • Department of Conservative Dentistry and Endodontics, Advanced and Digital Endodontic, Restorative and Prosthodontic Treatment (TADERP) Research Center, Faculty of Dental Medicine, "Victor Babeș" University of Medicine…
  • Faculty of Dental Medicine, "Victor Babeș" University of Medicine and Pharmacy, Eftimie Murgu Square 2, 300041 Timișoara, Romania.
  • Department of Prosthodontics, TADERP Research Center, "Victor Babeș" University of Medicine and Pharmacy, B-dul Revoluției 1989, No. 9, 300041 Timișoara, Romania.

ORCID-Profile: Flavius-Alexandru Sinitean, Luminița-Maria Nica, Anca Jivănescu

Förderung

  • “Victor Babeș” University of Medicine and Pharmacy Timișoara

Zitieren

APA

Sinitean, F. A., Nica, L. M., Cîrligeriu, L. E., & Jivănescu, A. (2026). Evaluation of Fiber Contamination from Different Microapplicators in Universal Adhesive Systems: A Pilot In Vitro Study. Materials, 19(12), 2562. https://doi.org/10.3390/ma19122562

Vancouver

Sinitean FA, Nica LM, Cîrligeriu LE, Jivănescu A. Evaluation of Fiber Contamination from Different Microapplicators in Universal Adhesive Systems: A Pilot In Vitro Study. Materials. 2026;19(12):2562. doi:10.3390/ma19122562

BibTeX
@article{Sinitean2026,
  author = {Sinitean, Flavius-Alexandru and Nica, Luminița-Maria and Cîrligeriu, Laura-Elena and Jivănescu, Anca},
  title = {Evaluation of Fiber Contamination from Different Microapplicators in Universal Adhesive Systems: A Pilot In Vitro Study},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {12},
  pages = {2562},
  doi = {10.3390/ma19122562}
}
Kostenlos starten →