Comparison of Surface Integrity and Fatigue Performance on TC17 Titanium Alloy After Shot Peening and Re-Shot Peening
Materials · 16.05.2026 · 19 (10) · 2090
DOI: 10.3390/ma19102090 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 16.05.2026. Verfasst von Chengsong Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of 3D Printing, Xinxiang University, Xinxiang 453003, China. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Henan Science and Technology Department, Science and Technology Research Project of Henan Province.
Abstract (Originalsprache)
In this study, we have systematically investigated how both shot peening (SP) and re-shot peening (RSP) affect the surface integrity and fatigue performance of TC17 titanium alloy. Surface integrity involves a competitive mechanism with the coexistence of beneficial and detrimental factors, both of which collectively determine the fatigue performance. While compressive residual stress (CRS), dislocation multiplication, and work hardening serve as beneficial factors, surface roughness and surface damage act as the detrimental factors. The results reveal high-intensity SP produced a deeper work-hardened layer. However, it also caused larger surface roughness and more severe surface damage, yielding the relaxation of the surface CRS and poorer improvement of the fatigue performance than that achieved with medium-intensity peening. The RSP treatment demonstrated a superior balance of surface integrity factors by effectively reducing the degree of surface damage and elevating the magnitude of surface CRS. Thus, a 45.9-fold improvement in fatigue life was achieved relative to the base material (BM) specimen. Surface CRS was identified as the primary factor contributing to the enhanced fatigue performance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of 3D Printing, Xinxiang University, Xinxiang 453003, China.
- National & Local Joint Engineering Laboratory for High-Performance Metal Structure Materials and Advanced Manufacturing Technology, Guizhou University, Guiyang 550025, China.
Förderung
- Henan Science and Technology Department
- Science and Technology Research Project of Henan Province
Zitieren
APA
Liu, C., Ma, P., Liu, P., Liu, D., & Guo, J. (2026). Comparison of Surface Integrity and Fatigue Performance on TC17 Titanium Alloy After Shot Peening and Re-Shot Peening. Materials, 19(10), 2090. https://doi.org/10.3390/ma19102090
Vancouver
Liu C, Ma P, Liu P, Liu D, Guo J. Comparison of Surface Integrity and Fatigue Performance on TC17 Titanium Alloy After Shot Peening and Re-Shot Peening. Materials. 2026;19(10):2090. doi:10.3390/ma19102090
BibTeX
@article{Liu2026,
author = {Liu, Chengsong and Ma, Pengfei and Liu, Pengfei and Liu, Dan and Guo, Jiale},
title = {Comparison of Surface Integrity and Fatigue Performance on TC17 Titanium Alloy After Shot Peening and Re-Shot Peening},
journal = {Materials},
year = {2026},
volume = {19},
number = {10},
pages = {2090},
doi = {10.3390/ma19102090}
}