Fachartikel in der Zeitschrift Materials, online erschienen am 24.04.2026. Verfasst von Yao Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Tai'an Taishan High Voltage Switchgear Co., Ltd., No. 50 Boyang Road, Taishan District, Tai'an 271000, China. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Smart Grid-National Science and Technology Major Project, Postdoctoral Fellowship Program (Grade C) of China Postdoctoral Science Foundation.
Abstract (Originalsprache)
In ultra-high-voltage GIS and GIL systems, epoxy resin insulators are still the mainstream choice. However, as a thermosetting material, epoxy resin is difficult to recycle after disposal, which limits its environmental benefits. Thermoplastic insulators, due to their recyclability, are potential alternatives. This study focuses on 30% glass fiber-reinforced PET and PA6 materials. Their injection molding behavior, hydraulic pressure performance, and insulation performance were systematically analyzed using Moldflow, ANSYS, and COMSOL, respectively. For injection molding, Moldflow simulations were conducted for filling, packing, and cooling stages. Melt temperature was varied from 260 to –310 °C (PET) and 250–300 °C (PA6), while mold temperature was varied from 80 to –130 °C (PET) and 70–120 °C (PA6). An optimization objective function, Y = Δp/20 + Δx/0.5 + Δs/1.8, was developed to determine optimal processing parameters. Based on this function, the optimal parameters identified are: PET at 290 °C melt temperature and 120 °C mold temperature; PA6 at 250 °C melt temperature and 70 °C mold temperature. For hydraulic testing, Moldflow–ANSYS coupled simulations were performed under 2.4 MPa pressure with the compliance criteria of bulk stress < 90 MPa and insert-contact stress < 20 MPa. PA6 passed within a processing window of melt temperature < 270 °C and mold temperature < 120 °C. PET failed under all tested conditions, with insert-contact stress ranging from 24.25 to 27.55 MPa, consistently exceeding the 20 MPa threshold. In terms of insulation performance, this paper utilizes COMSOL to study the electric field distribution of thermoplastic insulators in SF6 GIS/GIL and provides optimization suggestions for insulator geometry design. This study systematically compares the injection molding processes and hydraulic pressure performance of PET and PA6 thermoplastic insulators. These results provide important process insights and design guidance for evaluating thermoplastic materials as potential alternatives to epoxy resin in GIS/GIL applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Tai'an Taishan High Voltage Switchgear Co., Ltd., No. 50 Boyang Road, Taishan District, Tai'an 271000, China.
- Department of Electrical Engineering, Tsinghua University, Beijing 100084, China.
- Department of Mechanical and Electrical Engineering, Beijing Information Science and Technology University, Beijing 100192, China.
ORCID-Profile: Xiaofei Chen, Weiqi Qin
Förderung
- Smart Grid-National Science and Technology Major Project
- Postdoctoral Fellowship Program (Grade C) of China Postdoctoral Science Foundation
Zitieren
APA
Wang, Y., Fu, Y., Chen, X., Zhang, Z., & Qin, W. (2026). Comparative Study on Injection Molding and Performance of Glass Fiber-Reinforced PET and PA6 Thermoplastic Insulators. Materials, 19(9), 1729. https://doi.org/10.3390/ma19091729
Vancouver
Wang Y, Fu Y, Chen X, Zhang Z, Qin W. Comparative Study on Injection Molding and Performance of Glass Fiber-Reinforced PET and PA6 Thermoplastic Insulators. Materials. 2026;19(9):1729. doi:10.3390/ma19091729
BibTeX
@article{Wang2026,
author = {Wang, Yao and Fu, Yuliang and Chen, Xiaofei and Zhang, Zehao and Qin, Weiqi},
title = {Comparative Study on Injection Molding and Performance of Glass Fiber-Reinforced PET and PA6 Thermoplastic Insulators},
journal = {Materials},
year = {2026},
volume = {19},
number = {9},
pages = {1729},
doi = {10.3390/ma19091729}
}
EUVIMED