EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design Method for Combined Shear Connectors in Steel–UHPC Composite Beams

Jingnan Ding, Tiange Gao, Jinsong Zhu iD

Materials · 09.04.2026 · 19 (8) · 1498

DOI: 10.3390/ma19081498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 09.04.2026. Verfasst von Jingnan Ding und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil Engineering, Shandong Jianzhu University, Jinan 250101, China. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DEPARTMENT OF SCIENCE AND TECHNOLOGY SHANDONG PROYINCE NAME OF FUNDER, Shandong Key Laboratory of Civil Engineering Disaster Prevention and Mitigation (Shandong University of Science and Technology), DEPARTMENT OF SCIENCE AND TECHNOLOGY SHANDONG PROVINCE.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Steel–UHPC composite beams are widely used in bridge engineering due to their high strength, durability, and suitability for prefabricated construction. However, the mechanical performance of shear connectors in UHPC differs significantly, and the uniform use of a single connector type along the beam span may result in a mismatch between connector mechanical characteristics and regional force demands, leading to suboptimal force transfer and inefficient utilization of connector capacity along the beam span. While previous studies have mainly focused on the local behavior of individual connectors, a system-level design strategy considering regional force demands is still limited. This study proposes a system-level design method for combined shear connectors in steel–UHPC composite beams, in which headed stud connectors and trapezoidal composite dowel connectors are arranged according to bending moment distribution and interface shear demand, thereby integrating connector mechanical characteristics with the spatial variation in internal forces along the beam span. The design procedure includes shear span division, longitudinal interface shear calculation, and resistance verification of different connector types. The method is applied to a practical steel–UHPC composite beam in a long-span approach bridge. Results show that headed studs provide reliable uplift resistance and ductile behavior in negative bending regions, whereas composite dowel connectors are shown to be more suitable for shear-dominated positive bending regions due to their higher shear capacity and stiffness. The combined system ensures effective composite action under different stress states and reduces total connector steel consumption compared with a stud-only layout. The proposed approach advances connector design toward performance-oriented and system-level structural optimization, providing a practical framework for connector arrangement in steel–UHPC composite beams.

Schlagwörter

Stichwörter der Autor:innen

bridge engineeringcombined connectorscomposite dowel connectorheaded studsteel–UHPC composite beam

Autor:innen und Institutionen

  • School of Civil Engineering, Shandong Jianzhu University, Jinan 250101, China.
  • Key Lab of Building Structural Retrofitting and Underground Space Engineering of the Ministry of Education, Shandong Jianzhu University, Jinan 250101, China.
  • School of Civil Engineering, Tianjin University, Tianjin 300072, China.
  • Key Laboratory of Coast Civil Structure Safety of Ministry of Education, Tianjin University, Tianjin 300072, China.

ORCID-Profile: Jinsong Zhu

Förderung

  • DEPARTMENT OF SCIENCE AND TECHNOLOGY SHANDONG PROYINCE NAME OF FUNDER
  • Shandong Key Laboratory of Civil Engineering Disaster Prevention and Mitigation (Shandong University of Science and Technology)
  • DEPARTMENT OF SCIENCE AND TECHNOLOGY SHANDONG PROVINCE

Zitieren

APA

Ding, J., Gao, T., & Zhu, J. (2026). Design Method for Combined Shear Connectors in Steel–UHPC Composite Beams. Materials, 19(8), 1498. https://doi.org/10.3390/ma19081498

Vancouver

Ding J, Gao T, Zhu J. Design Method for Combined Shear Connectors in Steel–UHPC Composite Beams. Materials. 2026;19(8):1498. doi:10.3390/ma19081498

BibTeX
@article{Ding2026,
  author = {Ding, Jingnan and Gao, Tiange and Zhu, Jinsong},
  title = {Design Method for Combined Shear Connectors in Steel–UHPC Composite Beams},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {8},
  pages = {1498},
  doi = {10.3390/ma19081498}
}
Kostenlos starten →