EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Behaviour of a Preloaded Asymmetric Multi-Bolted Connection Under Cyclic Loads by Experimental Research

Rafał Grzejda iD, Arkadiusz Parus iD, Konrad Kwiatkowski iD

Materials · 01.04.2026 · 19 (7) · 1414

DOI: 10.3390/ma19071414 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 01.04.2026. Verfasst von Rafał Grzejda und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, 70-310 Szczecin, Poland. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper reports on experimental investigations of a preloaded asymmetrical multi-bolted connection under operating conditions. At the beginning of the tests, the bolts were preloaded in a predetermined optimal order, in three passes, monitoring the bolt force values by means of a calibrated measuring system with strain gauges. The main tests were carried out on an Instron 8850 testing machine. The connection was subjected to sinusoidal loads with amplitudes of 10 kN and 20 kN at various frequencies. The data obtained was collected and recorded using prepared measurement pathway components, and then processed in MATLAB/Simulink R2018b. The observed measurement results are depicted in graphs displaying the distribution of forces in bolts as a function of cyclically varying operating loads. We have demonstrated that the forces in bolts also vary cyclically relative to their initial preload values. Due to the asymmetry of the connection, this variation was different for individual bolts. The results show bolt force deviations within ±2% and confirm the stability of the connection under cyclic operating loads. The presented results complement the database of experimental results, on the basis of which we will validate the systemic approach to modelling multi-bolted connections.

Schlagwörter

Stichwörter der Autor:innen

bolt force monitoringcyclic loadingmulti-bolted connectionpreloadresistance strain gauges

Autor:innen und Institutionen

  • Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, 70-310 Szczecin, Poland.

ORCID-Profile: Rafał Grzejda, Arkadiusz Parus, Konrad Kwiatkowski

Zitieren

APA

Grzejda, R., Parus, A., & Kwiatkowski, K. (2026). Behaviour of a Preloaded Asymmetric Multi-Bolted Connection Under Cyclic Loads by Experimental Research. Materials, 19(7), 1414. https://doi.org/10.3390/ma19071414

Vancouver

Grzejda R, Parus A, Kwiatkowski K. Behaviour of a Preloaded Asymmetric Multi-Bolted Connection Under Cyclic Loads by Experimental Research. Materials. 2026;19(7):1414. doi:10.3390/ma19071414

BibTeX
@article{Grzejda2026,
  author = {Grzejda, Rafał and Parus, Arkadiusz and Kwiatkowski, Konrad},
  title = {Behaviour of a Preloaded Asymmetric Multi-Bolted Connection Under Cyclic Loads by Experimental Research},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {7},
  pages = {1414},
  doi = {10.3390/ma19071414}
}
Kostenlos starten →