Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections

Geon-Woo Kim, Jong-Kook Hong iD

Materials · 31.03.2026 · 19 (7) · 1401

DOI: 10.3390/ma19071401 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 31.03.2026. Verfasst von Geon-Woo Kim und 1 weiteren Autor:innen. Beteiligte Einrichtung: MS Construction Technology Co., Ltd., 77 Yongbong-ro, Gwangju 61186, Republic of Korea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the influence of out-of-plane beam skew on the cyclic performance of column-tree steel moment connections. Utilizing validated finite element (FE) models against experimental data, the cyclic responses of various configurations were evaluated under the AISC cyclic loading protocol up to a story drift ratio of 0.05 rad. Skew angles of 0°, 10°, 20°, and 30° were examined across three representative beam depths. The results demonstrate that all configurations satisfy the AISC 341 acceptance criteria for Special Moment Frames (SMFs), maintaining at least 80% of the plastic moment capacity (0.8 Mp) up to a 0.04 rad story drift ratio. However, the introduction of beam skew resulted in a gradual reduction in energy dissipation capacity, with the total dissipated energy decreasing by 2.9–8.9% at a 30° skew. Notably, the inelastic energy component was more sensitive to the skew than the frictional components, exhibiting a maximum reduction of 15.4%. While out-of-plane skew disrupted the symmetry of stress triaxiality and plastic strain at the beam-to-column interface, the overall fracture susceptibility was not significantly exacerbated up to 30°. Furthermore, column twisting remained within a negligible range (below 0.5°), and its impact on global stability was limited. Despite the general stability, a premature bolted splice failure was observed in deep beam configurations at a 30° skew during the 0.05 rad drift cycles. Based on these findings, it is concluded that column-tree connections with an out-of-plane skew up to 30° are viable; however, a design limit of 20° is recommended for deep beam configurations to ensure structural integrity under extreme cyclic demands.

Schlagwörter

Stichwörter der Autor:innen

bolted splicecolumn treecyclic loadingfinite element analysisout-of-plane skewsteel moment connection

Autor:innen und Institutionen

  • MS Construction Technology Co., Ltd., 77 Yongbong-ro, Gwangju 61186, Republic of Korea.
  • School of Architecture, Sunchon National University, 255 Jungang-ro, Suncheon 57922, Republic of Korea.

ORCID-Profile: Jong-Kook Hong

Zitieren

APA

Kim, G. W., & Hong, J. K. (2026). Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections. Materials, 19(7), 1401. https://doi.org/10.3390/ma19071401

Vancouver

Kim GW, Hong JK. Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections. Materials. 2026;19(7):1401. doi:10.3390/ma19071401

BibTeX
@article{Kim2026,
  author = {Kim, Geon-Woo and Hong, Jong-Kook},
  title = {Out-of-Plane Skew Effects on the Cyclic Performance of Column-Tree Steel Moment Connections},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {7},
  pages = {1401},
  doi = {10.3390/ma19071401}
}
Kostenlos starten →