Hybrid Steel Fiber Design in Ultra-High-Performance Concrete Containing Coarse Aggregate Using Pore Size Distribution Within Coarse Aggregate Skeleton
Materials · 21.03.2026 · 19 (6) · 1248
DOI: 10.3390/ma19061248 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 21.03.2026. Verfasst von Rui Tang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil Engineering, Central South University, Changsha 410075, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
To address the challenge of coarse aggregates hindering steel fiber dispersion and reducing toughening efficiency in ultra-high-performance concrete containing coarse aggregate (UHPC-CA), this study proposes a hybrid fiber design method based on reverse adaptation to the aggregate structure: a paradigm where fiber proportions are inversely designed to match the quantified void size distribution within the coarse aggregate skeleton. Industrial X-ray computed tomography (X-CT) was employed to capture the internal structure of UHPC-CA. Digital image processing techniques were used to quantitatively characterize the size distribution within the coarse aggregate skeleton gap. Based on this distribution, the blending proportions of multi-scale (3–16 mm) copper-plated steel fibers were systematically determined. Three fiber configurations were compared: mono-sized 13 mm fibers (Type A), an empirical model based on aggregate size (Type B), and a quantitatively designed blend based on skeleton gap distribution (Type C). At the same fiber volume fraction, the mechanical property test results show that the C type achieves approximately 18.6% higher flexural strength and 29.1% higher splitting tensile strength compared to the A type, while showing 5.3% and 6.7% improvements over the B type, and the compressive strength also increased slightly (about 3.0%). The microanalysis further confirms that the fiber distribution in the C-type design was more uniform, and the bridging effect and crack resistance were more sufficient. The proposed gap-adaptive fiber design paradigm offers an effective approach for optimizing reinforcement distribution in composites, providing theoretical and practical value for high-performance UHPC-CA applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Civil Engineering, Central South University, Changsha 410075, China.
- Central & Southern China Municipal Engineering Design and Research Institute Co., Ltd., Wuhan 430010, China.
- Technology Department, Hunan Automotive Engineering Vocational University, Zhuzhou 412001, China.
ORCID-Profile: Yinfei Du
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Tang, R., Du, Y., Zhang, J., & Kong, L. (2026). Hybrid Steel Fiber Design in Ultra-High-Performance Concrete Containing Coarse Aggregate Using Pore Size Distribution Within Coarse Aggregate Skeleton. Materials, 19(6), 1248. https://doi.org/10.3390/ma19061248
Vancouver
Tang R, Du Y, Zhang J, Kong L. Hybrid Steel Fiber Design in Ultra-High-Performance Concrete Containing Coarse Aggregate Using Pore Size Distribution Within Coarse Aggregate Skeleton. Materials. 2026;19(6):1248. doi:10.3390/ma19061248
BibTeX
@article{Tang2026,
author = {Tang, Rui and Du, Yinfei and Zhang, Jian and Kong, Lingxiang},
title = {Hybrid Steel Fiber Design in Ultra-High-Performance Concrete Containing Coarse Aggregate Using Pore Size Distribution Within Coarse Aggregate Skeleton},
journal = {Materials},
year = {2026},
volume = {19},
number = {6},
pages = {1248},
doi = {10.3390/ma19061248}
}
EUVIMED