EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterisation of Scale Deposits in Drinking Water Pipes by FTIR and ICP-OES

Paweł Wiercik iD, Justyna Stańczyk iD, Justyna Możejko

Materials · 20.03.2026 · 19 (6) · 1223

DOI: 10.3390/ma19061223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 20.03.2026. Verfasst von Paweł Wiercik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Environmental Engineering, The Faculty of Environmental Engineering and Geodesy, Wrocław University of Environmental and Life Sciences, …. Die Arbeit nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Attenuated Total Reflection–Fourier Transform Infrared (ATR-FTIR) spectroscopy and Inductively Coupled Plasma–Optical Emission Spectrometry (ICP-OES) are widely used to investigate the chemical structure and elemental composition of materials. However, the combined application of both methods to examine scale deposits in the water supply network has not yet been explored. In this study, scale deposits collected from the inlets of six pipes (steel, cast iron, lead, wooden) were analysed using both techniques. The application of ATR-FTIR and ICP-OES enabled the identification of mineral phases, organics, and structural differences between individual scale layers. Iron oxyhydroxides, together with silica and aluminosilicates, dominated most samples, whereas shower faucet deposit was primarily composed of carbonates and stearates. The combined analytical approach helped to avoid misinterpretation of FTIR data: although the spectrum of lead pipe deposit resembled hydrated lead carbonates, ICP-OES revealed only trace amounts of lead. Differences in crystallinity between successive layers allowed the reconstruction of the deposition process within the pipes. Poorly crystalline iron oxyhydroxides and silica occurred near pipe walls, while more crystalline phases developed closer to the water interface. These results demonstrate that combining ATR-FTIR and ICP-OES provides a reliable framework for interpreting scale deposit composition and formation in water distribution systems.

Schlagwörter

Stichwörter der Autor:innen

FTIR spectroscopyICP-OES spectroscopybiofilmcorrosionscale depositswater supply network

Autor:innen und Institutionen

  • Institute of Environmental Engineering, The Faculty of Environmental Engineering and Geodesy, Wrocław University of Environmental and Life Sciences, Grunwaldzki Square 24, 50-363 Wrocław, Poland.
  • ENTAL Instalacje Sp. Z o.o., 18 Kolejowa St., 47-400 Racibórz, Poland.

ORCID-Profile: Paweł Wiercik, Justyna Stańczyk

Zitieren

APA

Wiercik, P., Stańczyk, J., & Możejko, J. (2026). Characterisation of Scale Deposits in Drinking Water Pipes by FTIR and ICP-OES. Materials, 19(6), 1223. https://doi.org/10.3390/ma19061223

Vancouver

Wiercik P, Stańczyk J, Możejko J. Characterisation of Scale Deposits in Drinking Water Pipes by FTIR and ICP-OES. Materials. 2026;19(6):1223. doi:10.3390/ma19061223

BibTeX
@article{Wiercik2026,
  author = {Wiercik, Paweł and Stańczyk, Justyna and Możejko, Justyna},
  title = {Characterisation of Scale Deposits in Drinking Water Pipes by FTIR and ICP-OES},
  journal = {Materials},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {1223},
  doi = {10.3390/ma19061223}
}
Kostenlos starten →