Effects of Washing Conditions on PAH Removal Effectiveness in Firefighter Protective Clothing Materials
Materials · 30.08.2025 · 18 (17) · 4073
DOI: 10.3390/ma18174073 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 30.08.2025. Verfasst von Sylwia Maria Krzemińska und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, Czerniakowska 16, 00-701 Warsaw, Po…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Ministry of Family, Labour and Social Policy, Poland.
Abstract (Originalsprache)
This study analyzes the effects of washing conditions on polycyclic aromatic hydrocarbon (PAH) content in firefighter protective clothing. The analysis involved specially prepared textile packages made of materials used in such clothing: an outer shell, a moisture barrier membrane, and a thermal insulation lining. Package samples were subjected to simulated exposure to a selected group of PAH compounds. Ultra-high-performance liquid chromatography with fluorescence detection (UHPLC/FL) was applied to determine PAH content. The study showed that washing conditions (water temperature and the number of rinses) influenced the effectiveness of removal of chemical contaminants. The most favorable results were obtained for the washing process conducted at 60 °C with three rinse cycles, which resulted in the lowest concentration of total PAHs in the two examined types of textile packages (0.40 µg·g−1 and 0.60 µg·g−1 in the outer shell, 3.9 µg·g−1 and 6.2 µg·g−1 in the membrane, and 0.40 µg·g−1 and 0.41 µg·g−1 in the thermal lining of packages A and B, respectively). The higher washing temperature (60 °C) had a more favorable effect on average washing effectiveness as compared with the lower temperature (40 °C) in both the two- and three-rinse variants. The average washing effectiveness also varied according to the type of material and amounted to 70% and 54% for textile package types A and B, respectively.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Personal Protective Equipment, Central Institute for Labour Protection-National Research Institute, Czerniakowska 16, 00-701 Warsaw, Poland.
- Department of Chemical, Biological and Aerosol Hazards, Central Institute for Labour Protection-National Research Institute, Czerniakowska 16, Warsaw 00-701, Poland.
- Institute of Architecture of Textiles, Faculty of Material Technologies and Textile Design, Lodz University of Technology, Żeromskiego 116, Lodz 90-924, Poland.
- Centre for Evaluation and Scientific Communication, Central Institute for Labour Protection-National Research Institute, Czerniakowska 16, Warsaw 00-701, Poland.
ORCID-Profile: Sylwia Maria Krzemińska, Małgorzata Szewczyńska, Witold Sygocki
Förderung
- the Ministry of Family, Labour and Social Policy, Poland
Zitieren
APA
Krzemińska, S. M., Szewczyńska, M., Miśkiewicz, P., & Sygocki, W. (2025). Effects of Washing Conditions on PAH Removal Effectiveness in Firefighter Protective Clothing Materials. Materials, 18(17), 4073. https://doi.org/10.3390/ma18174073
Vancouver
Krzemińska SM, Szewczyńska M, Miśkiewicz P, Sygocki W. Effects of Washing Conditions on PAH Removal Effectiveness in Firefighter Protective Clothing Materials. Materials. 2025;18(17):4073. doi:10.3390/ma18174073
BibTeX
@article{Krzemiska2025,
author = {Krzemińska, Sylwia Maria and Szewczyńska, Małgorzata and Miśkiewicz, Pamela and Sygocki, Witold},
title = {Effects of Washing Conditions on PAH Removal Effectiveness in Firefighter Protective Clothing Materials},
journal = {Materials},
year = {2025},
volume = {18},
number = {17},
pages = {4073},
doi = {10.3390/ma18174073}
}
EUVIMED