High Thermal Conductivity Diamond–Copper Composites Prepared via Hot Pressing with Tungsten–Coated Interfacial Layer Optimization
Materials · 19.08.2025 · 18 (16) · 3882
DOI: 10.3390/ma18163882 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 19.08.2025. Verfasst von Qiang Wang und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Aeronautics, Chongqing Jiaotong University, Chongqing 400074, China. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Chongqing Municipal Education Commission Science and Technology Research Project.
Abstract (Originalsprache)
Diamond–copper composites, due to their exceptional thermal conductivity, hold significant potential in the field of electronic device thermal management. Hot-press sintering is a promising fabrication technique with industrial application prospects; however, the thermal conductivity of composites prepared by this method has yet to reach optimal levels. In this study, tungsten was deposited on the surface of diamond particles by magnetron sputtering as an interfacial transition layer, and hot-press sintering was employed to fabricate the composites. The findings reveal that with prolonged annealing time, tungsten gradually transformed into W2C and WC, significantly enhancing interfacial bonding strength. When the diamond volume content was 50% and the interfacial coating consisted of 2 wt.% W, 92 wt.% WC, and 6 wt.% W2C, the composite exhibited a thermal conductivity of 640 W/(m·K), the highest value reported among hot-press sintered composites with diamond content below 50%. Additionally, the AMM (Acoustic Mismatch Model) and DMM (Diffusion Mismatch Model) models were utilized to calculate the interfacial thermal conductance between different phases, identifying the optimal interfacial structure as diamond/W2C/WC/W2C/Cu. This composite material shows potential for application in high-power electronic device cooling, thermal management systems, and thermoelectric conversion, providing a more efficient thermal dissipation solution for related devices.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Aeronautics, Chongqing Jiaotong University, Chongqing 400074, China.
- Key Laboratory of Low-Grade Energy Utilization Technologies and Systems, Chongqing University, Ministry of Education, Chongqing 400044, China.
- Zhengzhou Research Institute, Harbin Institute of Technology, Zhengzhou 450000, China.
- Laboratory of Microwave and Vacuum Technology, Jihua Laboratory, Foshan 528200, China.
ORCID-Profile: Wenxin Cao
Förderung
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
- Chongqing Municipal Education Commission Science and Technology Research Project
- Key Research and Development Program of Heilongjiang Province
- Research and Innovation Program for Graduate Students in Chongqing
Zitieren
APA
Wang, Q., Ye, Z., Liu, L., Bai, J., Zhao, Y., Hu, Q., Liu, H., Hu, L., Guo, X., Xiao, Y., Cao, W., & Yang, Z. (2025). High Thermal Conductivity Diamond–Copper Composites Prepared via Hot Pressing with Tungsten–Coated Interfacial Layer Optimization. Materials, 18(16), 3882. https://doi.org/10.3390/ma18163882
Vancouver
Wang Q, Ye Z, Liu L, Bai J, Zhao Y, Hu Q, et al. High Thermal Conductivity Diamond–Copper Composites Prepared via Hot Pressing with Tungsten–Coated Interfacial Layer Optimization. Materials. 2025;18(16):3882. doi:10.3390/ma18163882
BibTeX
@article{Wang2025,
author = {Wang, Qiang and Ye, Zhijie and Liu, Lei and Bai, Jie and Zhao, Yuning and Hu, Qiang and Liu, Hong and Hu, Lang and Guo, Xiaodong and Xiao, Yongneng and Cao, Wenxin and Yang, Zhenhuai},
title = {High Thermal Conductivity Diamond–Copper Composites Prepared via Hot Pressing with Tungsten–Coated Interfacial Layer Optimization},
journal = {Materials},
year = {2025},
volume = {18},
number = {16},
pages = {3882},
doi = {10.3390/ma18163882}
}
EUVIMED