EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Corrosion Behavior of Shot Peened Ti6Al4V Alloy Fabricated by Conventional and Additive Manufacturing

Mariusz Walczak iD, Wojciech Okuniewski iD, Wojciech J Nowak iD, Dariusz Chocyk iD, Kamil Pasierbiewicz

Materials · 14.05.2025 · 18 (10) · 2274

DOI: 10.3390/ma18102274 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 14.05.2025. Verfasst von Mariusz Walczak und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Engineering, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36D, 20-618 Lublin, Poland. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Polish National Minister of Science and Higher Education, authors’ voucher.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ti6Al4V titanium alloy is one of the most studied for its properties after additive manufacturing. Due to its widely use in medical applications, its properties are investigated in various aspects of surface layer property improvement and later compared to conventionally manufactured Ti-6Al-4V. In this study, the corrosion behavior in a 0.9% NaCl solution of shot peened Ti-6Al-4V prepared using direct metal laser sintering (DMLS) was examined using corrosion electrochemical testing and compared with conventionally forged titanium alloy. Shot peening was performed on previously polished samples and subsequently treated with the CrNi steel shots. Two sets of peening pressure were selected: 0.3 and 0.4 MPa. X-ray diffraction analysis (XRD), X-ray micro-computed tomography (Micro-CT), scanning electron microscope (SEM) tests with roughness and hardness measurements were used to characterize the samples. The conventional samples were characterized by an α + β structure, while the additive samples had an α’ + β martensitic structure. The obtained results indicate that the corrosion resistance of the conventionally forged Ti-6Al-4V alloy was higher than DMLSed Ti-6Al-4V alloy. The lowest corrosion rates were noted for untreated surfaces of CM/ref and DMLS/ref samples and reached 0.041 and 0.070 µA/cm2, respectively. Moreover, the development of the surface has an influence on corrosion behavior. Therefore, increasing pressure results in inferior corrosion resistance. However, better performance for shot peened samples was reported in the low frequency range. This is due to the refinement of the grain acquired after the peening process. All the results obtained, related to the corrosion behavior, were satisfactory enough that the all samples can be characterized as materials suitable for implant applications.

Schlagwörter

Stichwörter der Autor:innen

DMLSadditive manufacturingcorrosionelectrochemistrytitanium alloy

Autor:innen und Institutionen

  • Department of Materials Engineering, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36D, 20-618 Lublin, Poland.
  • Department of Materials Engineering, Faculty of Mechanical Engineering, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland.
  • Department of Applied Physics, Faculty of Mechanical Engineering, Lublin University of Technology, Nadbystrzycka 36D, 20-618 Lublin, Poland.
  • Faculty of Transport and Computer Science, WSEI University in Lublin, ul. Projektowa 4, 20-209 Lublin, Poland.

ORCID-Profile: Mariusz Walczak, Wojciech Okuniewski, Wojciech J Nowak, Dariusz Chocyk

Förderung

  • Polish National Minister of Science and Higher Education
  • authors’ voucher

Zitieren

APA

Walczak, M., Okuniewski, W., Nowak, W. J., Chocyk, D., & Pasierbiewicz, K. (2025). Corrosion Behavior of Shot Peened Ti6Al4V Alloy Fabricated by Conventional and Additive Manufacturing. Materials, 18(10), 2274. https://doi.org/10.3390/ma18102274

Vancouver

Walczak M, Okuniewski W, Nowak WJ, Chocyk D, Pasierbiewicz K. Corrosion Behavior of Shot Peened Ti6Al4V Alloy Fabricated by Conventional and Additive Manufacturing. Materials. 2025;18(10):2274. doi:10.3390/ma18102274

BibTeX
@article{Walczak2025,
  author = {Walczak, Mariusz and Okuniewski, Wojciech and Nowak, Wojciech J and Chocyk, Dariusz and Pasierbiewicz, Kamil},
  title = {Corrosion Behavior of Shot Peened Ti6Al4V Alloy Fabricated by Conventional and Additive Manufacturing},
  journal = {Materials},
  year = {2025},
  volume = {18},
  number = {10},
  pages = {2274},
  doi = {10.3390/ma18102274}
}
Kostenlos starten →