Finite Element Analysis of Implant Stability Quotient (ISQ) and Bone Stresses for Implant Inclinations of 0°, 15°, and 20°

Mario Ceddia iD, Tea Romasco iD, Giulia Marchioli iD, Luca Comuzzi iD, Alessandro Cipollina iD, Adriano Piattelli, Luciano Lamberti, Natalia Di Pietro iD, Bartolomeo Trentadue iD

Materials · 02.04.2025 · 18 (7) · 1625

DOI: 10.3390/ma18071625 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 02.04.2025. Verfasst von Mario Ceddia und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to utilize finite element analysis (FEA) to evaluate the primary stability of Cyroth dental implants (AoN Implants Srl, Grisignano di Zocco, Italy) under various biomechanical conditions, including different implant inclinations (0°, 15°, and 20°) and bone densities (D3 and D4). By comparing these results with those obtained from in vitro tests on polyurethane blocks, the study sought to determine whether FEA could provide stability information more quickly and efficiently than in vitro methods. The research involved correlating dental implant micro-mobility with the implant stability quotient (ISQ) using FEA to simulate the mechanical behavior of implants and the surrounding bone tissue. Additionally, the study assessed the error in ISQ value detection by comparing FEA results with in vitro tests on polyurethane blocks conducted under the same experimental conditions. Both the FEA simulations and in vitro experiments demonstrated similar trends in ISQ values. For the D3 bone block simulated by FEA, the difference from the in vitro test was only 1.27%, while for the D2 bone, the difference was 2.86%. The findings also indicated that ISQ increases with implant inclination and that bone quality significantly affects primary stability, with ISQ decreasing as bone density diminishes. Overall, this study showed that ISQ evaluation for dental implants can be effectively performed through FEA, particularly by examining micro-movements. The results indicated that FEA and in vitro polyurethane testing yielded comparable outcomes, with FEA providing a faster and more cost-effective means of assessing ISQ across various clinical scenarios compared to in vitro testing.

Schlagwörter

Stichwörter der Autor:innen

dental implantsfinite element analysis (FEA)implant stability quotient (ISQ)inclinationpolyurethanestress distribution

Autor:innen und Institutionen

  • Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.
  • Department of Medical, Oral and Biotechnological Sciences, "G. d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy.
  • Center for Advanced Studies and Technologies (CAST), "G. d'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy.
  • Independent Researcher, 31020 San Vendemiano, Italy.
  • Independent Researcher, 92019 Sciacca, Italy.
  • School of Dentistry, Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy.

ORCID-Profile: Mario Ceddia, Tea Romasco, Giulia Marchioli, Luca Comuzzi, Alessandro Cipollina, Natalia Di Pietro, Bartolomeo Trentadue

Zitieren

APA

Ceddia, M., Romasco, T., Marchioli, G., Comuzzi, L., Cipollina, A., Piattelli, A., Lamberti, L., Di Pietro, N., & Trentadue, B. (2025). Finite Element Analysis of Implant Stability Quotient (ISQ) and Bone Stresses for Implant Inclinations of 0°, 15°, and 20°. Materials, 18(7), 1625. https://doi.org/10.3390/ma18071625

Vancouver

Ceddia M, Romasco T, Marchioli G, Comuzzi L, Cipollina A, Piattelli A, et al. Finite Element Analysis of Implant Stability Quotient (ISQ) and Bone Stresses for Implant Inclinations of 0°, 15°, and 20°. Materials. 2025;18(7):1625. doi:10.3390/ma18071625

BibTeX
@article{Ceddia2025,
  author = {Ceddia, Mario and Romasco, Tea and Marchioli, Giulia and Comuzzi, Luca and Cipollina, Alessandro and Piattelli, Adriano and Lamberti, Luciano and Di Pietro, Natalia and Trentadue, Bartolomeo},
  title = {Finite Element Analysis of Implant Stability Quotient (ISQ) and Bone Stresses for Implant Inclinations of 0°, 15°, and 20°},
  journal = {Materials},
  year = {2025},
  volume = {18},
  number = {7},
  pages = {1625},
  doi = {10.3390/ma18071625}
}
Kostenlos starten →