EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Parameters Tailoring on the Deposition of Hydroxyapatite by Pulsed Electrical Discharge

Stefan Alexandru Laptoiu, Mihai Ovidiu Cojocaru, Marian Miculescu iD, Mihai Branzei iD

Materials · 18.09.2024 · 17 (18) · 4583

DOI: 10.3390/ma17184583 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 18.09.2024. Verfasst von Stefan Alexandru Laptoiu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Metallic Materials Science and Physical Metallurgy, National University of Science and Technology Politehnica Bucharest, 060042 Buchare…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The creation of strong adhesive layers of hydroxyapatite-based bioceramics (with or without bioinert metals, such as Ta, Ag, and Ti) on biocompatible metallic supports enhances the local biofunctionalization of surfaces. The processing of electroconductive materials using electrical impulse discharges is versatile, enabling precise coating of selected areas with perfectly adherent layers of varying thicknesses. This study aims to quantify the effects of varying the electrical power from the source generating the impulse discharge and the specific processing time per unit area of the cathode (made of titanium alloy) on the relative mass increase of the cathode. The anode comprised a mixture of hydroxyapatite powder and a self-polymerizing electroconductive acrylic resin in a tantalum sheath. The effects of the parameter adjustments on single-layer deposition adherence were quantified using a central composite design to build a second-order orthogonal model. The most significant difference in relative mass was observed with a low-power source (5 W) ensuring the electrical discharge impulse, combined with the longest specified surface treatment time (17.5 s/cm2 on a 4 cm2 surface) for a single layer presenting the largest mass increase of 0.153% of the original mass. This study aimed to enhance the performance of medical implants by optimizing surface biofunctionalization through robust hydroxyapatite-based bioceramic adhesive layers on metallic supports, determining the optimal electrical power and processing time for cathode mass increase during deposition processes, and analyzing parameter adjustments using second-order statistical orthogonal central composite programming, with a focus on single-layer deposition to identify significant differences in relative mass under specific conditions.

Schlagwörter

Stichwörter der Autor:innen

biocompatible alloybioinert metalsdoped bioceramic layerelectrical impulse dischargeexperimental programminghydroxyapatiterelative mass variationsspecific surface processing timethe electrical power of the source

Autor:innen und Institutionen

  • Department of Metallic Materials Science and Physical Metallurgy, National University of Science and Technology Politehnica Bucharest, 060042 Bucharest, Romania.
  • Section IX-Materials Science and Engineering, Academia of Technical Science Romania, 010413 Bucharest, Romania.

ORCID-Profile: Marian Miculescu, Mihai Branzei

Zitieren

APA

Laptoiu, S. A., Cojocaru, M. O., Miculescu, M., & Branzei, M. (2024). Parameters Tailoring on the Deposition of Hydroxyapatite by Pulsed Electrical Discharge. Materials, 17(18), 4583. https://doi.org/10.3390/ma17184583

Vancouver

Laptoiu SA, Cojocaru MO, Miculescu M, Branzei M. Parameters Tailoring on the Deposition of Hydroxyapatite by Pulsed Electrical Discharge. Materials. 2024;17(18):4583. doi:10.3390/ma17184583

BibTeX
@article{Laptoiu2024,
  author = {Laptoiu, Stefan Alexandru and Cojocaru, Mihai Ovidiu and Miculescu, Marian and Branzei, Mihai},
  title = {Parameters Tailoring on the Deposition of Hydroxyapatite by Pulsed Electrical Discharge},
  journal = {Materials},
  year = {2024},
  volume = {17},
  number = {18},
  pages = {4583},
  doi = {10.3390/ma17184583}
}
Kostenlos starten →