EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Performance of Low-Dimensional Solid Room-Temperature Photodetectors—Critical View

Antoni Rogalski iD, Weida Hu iD, Fang Wang, Piotr Martyniuk iD

Materials · 14.09.2024 · 17 (18) · 4522

DOI: 10.3390/ma17184522 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Materials, online erschienen am 14.09.2024. Verfasst von Antoni Rogalski und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Applied Physics, Military University of Technology, 2 Kaliskiego Str., 00-908 Warsaw, Poland. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 136 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre (NCN), National Natural Science Foundation of China (NSFC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the last twenty years, nanofabrication progress has allowed for the emergence of a new photodetector family, generally called low-dimensional solids (LDSs), among which the most important are two-dimensional (2D) materials, perovskites, and nanowires/quantum dots. They operate in a wide wavelength range from ultraviolet to far-infrared. Current research indicates remarkable advances in increasing the performance of this new generation of photodetectors. The published performance at room temperature is even better than reported for typical photodetectors. Several articles demonstrate detectivity outperforming physical boundaries driven by background radiation and signal fluctuations. This study attempts to explain these peculiarities. In order to achieve this goal, we first clarify the fundamental differences in the photoelectric effects of the new generation of photodetectors compared to the standard designs dominating the commercial market. Photodetectors made of 2D transition metal dichalcogenides (TMDs), quantum dots, topological insulators, and perovskites are mainly considered. Their performance is compared with the fundamental limits estimated by the signal fluctuation limit (in the ultraviolet region) and the background radiation limit (in the infrared region). In the latter case, Law 19 dedicated to HgCdTe photodiodes is used as a standard reference benchmark. The causes for the performance overestimate of the different types of LDS detectors are also explained. Finally, an attempt is made to determine their place in the global market in the long term.

Schlagwörter

Stichwörter der Autor:innen

2D photodetectorsBLIPHOT photodetectorsSFLcolloidal quantum dot photodetectorsperovskite photodetectorsphotogating effecttopological insulator photodetectorsultraviolet photodetectors

Autor:innen und Institutionen

  • Institute of Applied Physics, Military University of Technology, 2 Kaliskiego Str., 00-908 Warsaw, Poland.
  • State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu Tian Road, Shanghai 200083, China.

ORCID-Profile: Antoni Rogalski, Weida Hu, Piotr Martyniuk

Förderung

  • National Science Centre (NCN)
  • National Natural Science Foundation of China (NSFC)

Zitieren

APA

Rogalski, A., Hu, W., Wang, F., & Martyniuk, P. (2024). Performance of Low-Dimensional Solid Room-Temperature Photodetectors—Critical View. Materials, 17(18), 4522. https://doi.org/10.3390/ma17184522

Vancouver

Rogalski A, Hu W, Wang F, Martyniuk P. Performance of Low-Dimensional Solid Room-Temperature Photodetectors—Critical View. Materials. 2024;17(18):4522. doi:10.3390/ma17184522

BibTeX
@article{Rogalski2024,
  author = {Rogalski, Antoni and Hu, Weida and Wang, Fang and Martyniuk, Piotr},
  title = {Performance of Low-Dimensional Solid Room-Temperature Photodetectors—Critical View},
  journal = {Materials},
  year = {2024},
  volume = {17},
  number = {18},
  pages = {4522},
  doi = {10.3390/ma17184522}
}
Kostenlos starten →