Perovskite versus Standard Photodetectors
Materials · 13.08.2024 · 17 (16) · 4029
DOI: 10.3390/ma17164029 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Materials, online erschienen am 13.08.2024. Verfasst von Antoni Rogalski und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Applied Physics, Military University of Technology, 2 Kaliskiego St., 00-908 Warsaw, Poland. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The National Science Centre, National Natural Science Foundation of China, Polish National Science Centre.
Abstract (Originalsprache)
Perovskites have been largely implemented into optoelectronics as they provide several advantages such as long carrier diffusion length, high absorption coefficient, high carrier mobility, shallow defect levels and finally, high crystal quality. The brisk technological development of perovskite devices is connected to their relative simplicity, high-efficiency processing and low production cost. Significant improvement has been made in the detection performance and the photodetectors’ design, especially operating in the visible (VIS) and near-infrared (NIR) regions. This paper attempts to determine the importance of those devices in the broad group of standard VIS and NIR detectors. The paper evaluates the most important parameters of perovskite detectors, including current responsivity (R), detectivity (D*) and response time (τ), compared to the standard photodiodes (PDs) available on the commercial market. The conclusions presented in this work are based on an analysis of the reported data in the vast pieces of literature. A large discrepancy is observed in the demonstrated R and D*, which may be due to two reasons: immature device technology and erroneous D* estimates. The published performance at room temperature is even higher than that reported for typical detectors. The utmost D* for perovskite detectors is three to four orders of magnitude higher than commercially available VIS PDs. Some papers report a D* close to the physical limit defined by signal fluctuations and background radiation. However, it is likely that this performance is overestimated. Finally, the paper concludes with an attempt to determine the progress of perovskite optoelectronic devices in the future.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Applied Physics, Military University of Technology, 2 Kaliskiego St., 00-908 Warsaw, Poland.
- State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu Tian Road, Shanghai 200083, China.
ORCID-Profile: Antoni Rogalski, Weida Hu, Piotr Martyniuk
Förderung
- The National Science Centre
- National Natural Science Foundation of China
- Polish National Science Centre
- Chinese Academy of Sciences (CAS) Hundred Talents Programme
Zitieren
APA
Rogalski, A., Hu, W., Wang, F., Wang, Y., & Martyniuk, P. (2024). Perovskite versus Standard Photodetectors. Materials, 17(16), 4029. https://doi.org/10.3390/ma17164029
Vancouver
Rogalski A, Hu W, Wang F, Wang Y, Martyniuk P. Perovskite versus Standard Photodetectors. Materials. 2024;17(16):4029. doi:10.3390/ma17164029
BibTeX
@article{Rogalski2024,
author = {Rogalski, Antoni and Hu, Weida and Wang, Fang and Wang, Yang and Martyniuk, Piotr},
title = {Perovskite versus Standard Photodetectors},
journal = {Materials},
year = {2024},
volume = {17},
number = {16},
pages = {4029},
doi = {10.3390/ma17164029}
}
EUVIMED