EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli

Liena Zaidan iD, Inna Novodchuk, Alexander H Xu, Alexandru Nica, Saeed Takaloo iD, Christopher Lloyd, Reza Karimi, Joe Sanderson, Michal Bajcsy, Mustafa Yavuz

Materials · 24.07.2024 · 17 (15) · 3648

DOI: 10.3390/ma17153648 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Materials, online erschienen am 24.07.2024. Verfasst von Liena Zaidan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.

Schlagwörter

Stichwörter der Autor:innen

E. coliFETbiosensorgraphene

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
  • Waterloo Institute for Nanotechnology (WIN), University of Waterloo, Waterloo, ON N2L 3G1, Canada.
  • Biograph Sense Inc., Kitchener, ON N2R 1V1, Canada.
  • National Institute for Materials Science (NIMS), University of Tsukuba, Tsukuba 305-0044, Ibaraki, Japan.
  • Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
  • RETEGO Bio Labs LLC, West Bountiful, UT 84087, USA.

ORCID-Profile: Liena Zaidan, Saeed Takaloo

Zitieren

APA

Zaidan, L., Novodchuk, I., H Xu, A., Nica, A., Takaloo, S., Lloyd, C., Karimi, R., Sanderson, J., Bajcsy, M., & Yavuz, M. (2024). Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli. Materials, 17(15), 3648. https://doi.org/10.3390/ma17153648

Vancouver

Zaidan L, Novodchuk I, H Xu A, Nica A, Takaloo S, Lloyd C, et al. Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli. Materials. 2024;17(15):3648. doi:10.3390/ma17153648

BibTeX
@article{Zaidan2024,
  author = {Zaidan, Liena and Novodchuk, Inna and H Xu, Alexander and Nica, Alexandru and Takaloo, Saeed and Lloyd, Christopher and Karimi, Reza and Sanderson, Joe and Bajcsy, Michal and Yavuz, Mustafa},
  title = {Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli},
  journal = {Materials},
  year = {2024},
  volume = {17},
  number = {15},
  pages = {3648},
  doi = {10.3390/ma17153648}
}
Kostenlos starten →