Load Capacity of Screw Anchor Installed in Concrete Substrate Reinforced with Steel Fibers Depending on Fiber Content
Materials · 28.02.2024 · 17 (5) · 1105
DOI: 10.3390/ma17051105 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 28.02.2024. Verfasst von Kazimierz Konieczny und 2 weiteren Autor:innen. Beteiligte Einrichtung: Building Research Institute (ITB), ul. Filtrowa 1, 00-611 Warsaw, Poland. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Pull-out strength tests conducted on screw anchors in uncracked concrete substrates of the C25/30 class are presented in this article. The destructive force for anchor–concrete fasting was tested, and in the next step, the average pull-out strengths of screw anchors in concrete substrates with and without the addition of steel fiber were determined. Currently, the pull-out strengths of anchors in fiber-reinforced concrete substrates are defined as for unreinforced concrete substrates. Therefore, pull-out tests were performed for screw anchors in fiber-reinforced concrete substrates. Fiber contents of 10, 20, 30, and 50 kg/m3 were used. An increase in the load capacity of screw anchors in a fiber-reinforced concrete substrate was demonstrated in a pull-out test compared to base samples without fibers. The coefficient related to the actual fastening behavior of a screw anchor in the fiber-reinforced concrete substrate was determined. It was assumed that a coefficient of 13.10 should be adopted. This was the lowest value obtained for the load capacity in this study for screw anchors in a fiber-reinforced concrete substrate.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Building Research Institute (ITB), ul. Filtrowa 1, 00-611 Warsaw, Poland.
ORCID-Profile: Daniel Dudek, Alfred Kukiełka
Zitieren
APA
Konieczny, K., Dudek, D., & Kukiełka, A. (2024). Load Capacity of Screw Anchor Installed in Concrete Substrate Reinforced with Steel Fibers Depending on Fiber Content. Materials, 17(5), 1105. https://doi.org/10.3390/ma17051105
Vancouver
Konieczny K, Dudek D, Kukiełka A. Load Capacity of Screw Anchor Installed in Concrete Substrate Reinforced with Steel Fibers Depending on Fiber Content. Materials. 2024;17(5):1105. doi:10.3390/ma17051105
BibTeX
@article{Konieczny2024,
author = {Konieczny, Kazimierz and Dudek, Daniel and Kukiełka, Alfred},
title = {Load Capacity of Screw Anchor Installed in Concrete Substrate Reinforced with Steel Fibers Depending on Fiber Content},
journal = {Materials},
year = {2024},
volume = {17},
number = {5},
pages = {1105},
doi = {10.3390/ma17051105}
}