Demagnetization Parameters Evaluation of Magnetic Shields Based on Anhysteretic Magnetization Curve
Materials · 26.07.2023 · 16 (15) · 5238
DOI: 10.3390/ma16155238 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 26.07.2023. Verfasst von Jianzhi Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing 100191, China. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Double First-class Guidance Project.
Abstract (Originalsprache)
To achieve the nearly zero-field environment, demagnetization is an indispensable step for magnetic shields composed of high-permeability material, which adjusts the magnetization of the material to establish magnetic equilibrium with the environmental field and improve the shielding performance. The ideal demagnetization can make the high-permeability material on the anhysteretic magnetization curve to have a higher permeability than on the initial magnetization curve. However, inappropriate parameters of degaussing field cause the magnetization state to deviate from the anhysteretic magnetization curve. Therefore, this article proposes a new assessment criterion to analyze and evaluate the parameters of degaussing field based on the difference between the final magnetization state after demagnetization and theoretical anhysteretic state of the shielding material. By this way, the magnetization states after demagnetizations with different initial amplitude, frequency, period number and envelope attenuation function are calculated based on the dynamic Jiles–Atherton (J–A) model, and their magnetization curves under these demagnetization conditions are also measured and compared, respectively. The lower frequency, appropriate amplitude, sufficient period number and logarithmic envelope attenuation function can make the magnetization state after demagnetization closer to the ideal value, which is also consistent with the static magnetic-shielding performance of a booth-type magnetically shielded room (MSR) under different demagnetization condition.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Beijing 100191, China.
- National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou 310051, China.
ORCID-Profile: Jianzhi Yang, Shuai Yuan
Förderung
- National Natural Science Foundation of China
- Double First-class Guidance Project
Zitieren
APA
Yang, J., Shi, M., Zhang, X., Ma, Y., Liu, Y., Yuan, S., & Han, B. (2023). Demagnetization Parameters Evaluation of Magnetic Shields Based on Anhysteretic Magnetization Curve. Materials, 16(15), 5238. https://doi.org/10.3390/ma16155238
Vancouver
Yang J, Shi M, Zhang X, Ma Y, Liu Y, Yuan S, et al. Demagnetization Parameters Evaluation of Magnetic Shields Based on Anhysteretic Magnetization Curve. Materials. 2023;16(15):5238. doi:10.3390/ma16155238
BibTeX
@article{Yang2023,
author = {Yang, Jianzhi and Shi, Minxia and Zhang, Xu and Ma, Yuzheng and Liu, Yijin and Yuan, Shuai and Han, Bangcheng},
title = {Demagnetization Parameters Evaluation of Magnetic Shields Based on Anhysteretic Magnetization Curve},