Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire
Materials · 11.01.2023 · 16 (2) · 708
DOI: 10.3390/ma16020708 ↗Kurz gefasst
Fachartikel in der Zeitschrift Materials, online erschienen am 11.01.2023. Verfasst von Yue Zhao und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Civil Engineering and Architecture, Xi'an University of Technology, Xi'an 710048, China. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Natural Science Basic Research Program of Shaanxi, the open fund of Shaanxi Provincial Key Laboratory (Chang'an University) of Highway Bridges and Tunnels.
Abstract (Originalsprache)
Cables are the main load-bearing components of a cable bridge and typically composed of high strength steel wires with a galvanized coating or Galfan coating. Galfan steel wire has recently started to be widely used because of its better corrosion resistance than galvanized steel wire. The corrosion characteristics of the coating and the difference in the corrosion fatigue process of the two types of steel wire are unclear. To further improve the service performance and maintenance of cable bridges, this study investigated the corrosion characteristics of galvanized steel wire and Galfan steel wire through accelerated corrosion tests and established a time-varying model of uniform corrosion and pitting corrosion of high-strength steel wire. Then, a long-span suspension bridge was taken as the research object, and the corrosion fatigue degradation of the two kinds of steel wire under a traffic load was analyzed on the basis of traffic monitoring data. The results showed that the uniform corrosion of the two types of steel wire conformed to an exponential development trend, the corrosion coefficient of galvanized steel wire conformed to the normal distribution, and the corrosion coefficient of Galfan steel wire conformed to the Cauchy distribution. The maximum pitting coefficient distribution of the two kinds of steel wire conformed to the generalized extreme value distribution. The location parameters and scale parameters of the two distributions showed an exponential downward trend with the increase of corrosion duration. When the traffic intensity was low, the corrosion characteristics of the steel wire was the main factor affecting its service life, and the average service life of Galfan steel wire was significantly higher than that of galvanized steel wire. Under a dense traffic flow, the service life of the steel wire was mainly controlled by the traffic load, and the service life of Galfan steel wire was slightly improved. Effective anti-corrosion measures are a key factor for improving the service life of steel wire.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Civil Engineering and Architecture, Xi'an University of Technology, Xi'an 710048, China.
- Xi'an Municipal Engineering Design & Research Institute Co., Ltd., Xi'an 710068, China.
- School of Architecture and Civil Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
ORCID-Profile: Yangguang Yuan
Förderung
- the Natural Science Basic Research Program of Shaanxi
- the open fund of Shaanxi Provincial Key Laboratory (Chang'an University) of Highway Bridges and Tunnels
Zitieren
APA
Zhao, Y., Su, B., Fan, X., Yuan, Y., & Zhu, Y. (2023). Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire. Materials, 16(2), 708. https://doi.org/10.3390/ma16020708
Vancouver
Zhao Y, Su B, Fan X, Yuan Y, Zhu Y. Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire. Materials. 2023;16(2):708. doi:10.3390/ma16020708
BibTeX
@article{Zhao2023,
author = {Zhao, Yue and Su, Botong and Fan, Xiaobo and Yuan, Yangguang and Zhu, Yiyun},
title = {Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire},
journal = {Materials},
year = {2023},
volume = {16},
number = {2},
pages = {708},
doi = {10.3390/ma16020708}
}