EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Hydraulic Axial Piston Pump Fault Diagnosis Based on Instantaneous Angular Speed under Non-Stationary Conditions

Jiamin Liu, Shuai Meng, Xintao Zhou, Lichen Gu

Lubricants · 17.09.2023 · 11 (9) · 406

DOI: 10.3390/lubricants11090406 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lubricants, online erschienen am 17.09.2023. Verfasst von Jiamin Liu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Introduce High-level Talents to Start Scientific Research Funds by Shaanxi Polytechnic Institute of China, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the intense noise interference in hydraulic systems, it is extremely difficult to detect component faults through vibration signals. Diagnostic performance is also constrained by highly time-varying and non-stationary operating conditions. This study proposes to use instantaneous angular speed (IAS) signals that are both operational and state parameters as sources of information. Firstly, the instantaneous angular speed fluctuation (IASF) of a piston pump is analyzed theoretically, and it is concluded that its fluctuating components contain the health status information of the components. The IASF can then be obtained by subtracting the speed trend term from IAS signals obtained via a magneto-electric speed sensor. A synchro-extraction of the normal S transform (SNST) is proposed to process it via line-pass filtering. Finally, the filtered and reconstructed IASF signal is utilized to draw a two-dimensional polar coordinate map online. A non-stationary-condition test is carried out on the test platform to monitor the morphological characteristics of the valve plate under normal, slight, and severe wear conditions. The polar plot shows significant increases in speed fluctuations and oscillation times within a range from 180° to 270°. The relevant research results reflect that the IAS signal can provide a new method for monitoring the operating status of and conducting fault diagnoses for hydraulic equipment.

Förderung

  • Introduce High-level Talents to Start Scientific Research Funds by Shaanxi Polytechnic Institute of China
  • National Natural Science Foundation of China

Zitieren

APA

Liu, J., Meng, S., Zhou, X., & Gu, L. (2023). A Hydraulic Axial Piston Pump Fault Diagnosis Based on Instantaneous Angular Speed under Non-Stationary Conditions. Lubricants, 11(9), 406. https://doi.org/10.3390/lubricants11090406

Vancouver

Liu J, Meng S, Zhou X, Gu L. A Hydraulic Axial Piston Pump Fault Diagnosis Based on Instantaneous Angular Speed under Non-Stationary Conditions. Lubricants. 2023;11(9):406. doi:10.3390/lubricants11090406

BibTeX
@article{Liu2023,
  author = {Liu, Jiamin and Meng, Shuai and Zhou, Xintao and Gu, Lichen},
  title = {A Hydraulic Axial Piston Pump Fault Diagnosis Based on Instantaneous Angular Speed under Non-Stationary Conditions},
  journal = {Lubricants},
  year = {2023},
  volume = {11},
  number = {9},
  pages = {406},
  doi = {10.3390/lubricants11090406}
}
Kostenlos starten →