EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing Lactate’s Role as a Predictor of Post-Transplant Outcomes During Normothermic Machine Perfusion

Rebecca Panconesi, Sangeeta Satish, Chase J. Wehrle, Mingyi Zhang, Keyue Sun, Chunbao Jiao, Omer F. Karakaya, Geofia Crasta, F. Selin Yildirim, Hiroshi Horie, Koki Takase, Nasim Eshraghi und 17 weitere

Livers · 10.07.2026 · 6 (4) · 67

DOI: 10.3390/livers6040067 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Livers, online erschienen am 10.07.2026. Verfasst von Rebecca Panconesi und 28 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Catalyst.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: The use of extended-criteria donors (ECDs) is rapidly increasing, with higher risks for impaired outcomes after liver transplantation (LT). Normothermic machine perfusion (NMP) can enhance graft viability assessment, though lactate clearance as a viability marker lacks consensus in clinical practice.

Methods

This study analyzed 213 adult liver transplants using NMP from October 2022 to January 2024. Perfusate lactate levels were measured with an Epoc® reader and five lactate-based viability criteria were evaluated for predicting post-LT outcomes.

Results

All livers cleared lactate at 6 h of NMP (median 0.51 mmol/L). However, 33 livers failed at least one lactate viability criterion. Thirteen livers (6.1%) were discarded based on traditional criteria, but discard rates would have been higher using Groningen (14.6%) or Brisbane (11.2%) criteria for lactate. Outcomes for the recipients of livers that failed the lactate criteria were comparable to those of recipients with livers meeting all criteria, including biliary complications (p = 0.63), graft survival (>0.99), and 6-month CCI (p = 0.89). ROC analysis revealed poor predictive value for graft survival for lactate clearance criteria (AUC 0.50), while lactate was outperformed by MEAF score (AUC 0.67).

Conclusions

Lactate clearance alone does not predict outcomes, highlighting the need for further validation of alternative viability.

Förderung

  • Catalyst

Zitieren

APA

Panconesi, R., Satish, S., Wehrle, C. J., Zhang, M., Sun, K., Jiao, C., Karakaya, O. F., Crasta, G., Yildirim, F. S., Horie, H., Takase, K., Eshraghi, N., Ali, K., Diwan, T., Liu, Q., Miyazaki, Y., Cazzaniga, B., Esfeh, J. M., Kwon, D. C. H., …, & Schlegel, A. (2026). Assessing Lactate’s Role as a Predictor of Post-Transplant Outcomes During Normothermic Machine Perfusion. Livers, 6(4), 67. https://doi.org/10.3390/livers6040067

Vancouver

Panconesi R, Satish S, Wehrle CJ, Zhang M, Sun K, Jiao C, et al. Assessing Lactate’s Role as a Predictor of Post-Transplant Outcomes During Normothermic Machine Perfusion. Livers. 2026;6(4):67. doi:10.3390/livers6040067

BibTeX
@article{Panconesi2026,
  author = {Panconesi, Rebecca and Satish, Sangeeta and Wehrle, Chase J. and Zhang, Mingyi and Sun, Keyue and Jiao, Chunbao and Karakaya, Omer F. and Crasta, Geofia and Yildirim, F. Selin and Horie, Hiroshi and Takase, Koki and Eshraghi, Nasim and Ali, Khaled and Diwan, Tobias and Liu, Qiang and Miyazaki, Yuki and Cazzaniga, Beatrice and Esfeh, Jamak Modaresi and Kwon, David C. H. and Aucejo, Federico and Khalil, Mazhar and Pita, Alejandro and Kim, JaeKeun and Fairchild, Robert L. and Fujiki, Masato and Pinna, Antonio D. and Miller, Charles and Hashimoto, Koji and Schlegel, Andrea},
  title = {Assessing Lactate’s Role as a Predictor of Post-Transplant Outcomes During Normothermic Machine Perfusion},
  journal = {Livers},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {67},
  doi = {10.3390/livers6040067}
}
Kostenlos starten →